INSTEK LCR-816 CALIBRATION and INSTEK LCR-816 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK LCR-816 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   INSTEK LCR-816   Description / Specification:    
INSTEK LCR-816 2 kHz Precision LCR Meter

The GW Instek LCR-816 is a high-end digital LCR meter for component/material measurements, applicable to various R&D activities and assembly lines. The large 240 x 128 dot matrix LCD display provides ample room for two measurement items and setup parameters. All test modes are able to measure supplementary factors, such as, R/Q, C/D, C/R, and L/Q. 100 sets of measurement setup memory allow sharing a single unit among multiple testing conditions or sites. For a better viewing experience in a standard PC monitor, proprietary Windows based software is accessible via the RS-232C terminal (optional). Specifications. Test Frequency: 100 Hz to 2 kHz (245 steps). Basic Accuracy: 0.1%. Test Speed: 68 ms. Test Signal Levels: 0.1 V to 1.275 Vrms ( 5 mV/step ). DC Bias Internal: 2 V. DC Bias External: 0 to 30 V. Display Range Resistance: 0.00001 ohm to 99999 k-ohm. Display Range Capacitance: 0.00001 pF to 99999 uF. Display Range Inductance: 0.00001 mH to 99999 H. Test Mode: R/Q, C/D, C/R, L/Q. Memory: 100 memory blocks total.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK LCR-816. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your INSTEK LCR-816 CALIBRATION and/or INSTEK LCR-816 2 kHz Precision LCR Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: