DESCO 19788 CALIBRATION and DESCO 19788 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the DESCO 19788 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   DESCO 19788   Description / Specification:    
DESCO 19788 Digital Surface Resistance Meter

The Desco 19788 Digital Surface Resistance Meter is an instrument designed to measure resistance point-to-point (Rtt) or surface to ground (Rtg) in accordance with ESD Association Standard ANSI/ESD S4.1. Its test funcitions include; Resistance measurement accuracy of ±10% (±20% for resistance values 1 x 10^11 and greater). Resistance range of <1 x 10^3 ohms to >1 x 10^12 ohms. Under load voltages of 10 and 100 volts ±5%. Electrification period of approximately 15 seconds. The Digital Surface Resistance Meter also measures ambient temperature and relative humidity. Specifications. Resistance Ranges: 1 x 10^3 - 1 x 10^12 ohms @ 10 Volts, complies with ANSI/ESD S4.1, 1 x 10^6 - 1 x 10^12 ohms @ 100 Volts, complies with ANSI/ESD S4.1. Accuracy: Resistance measurements within ±10% (±20% for resistance values 1 x 10^11 and greater), complies with ANSI/ESD-S4.1. Under load voltages of 10 Volts ± 5% and 100 Volts ± 5% exceed.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the DESCO 19788. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your DESCO 19788 CALIBRATION and/or DESCO 19788 Digital Surface Resistance Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: