ELGAR CW801M CALIBRATION and ELGAR CW801M REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ELGAR CW801M Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ELGAR CW801M   Description / Specification:   Spec Sheet 
ELGAR CW801M 0-135/270 Vrms, 3.0/6.0 ARMS Continuous Wave AC Power Source

The Elgar CW 801M ContinuousWave (CW) AC power sources provides clean single phase power. The front panel has two bright four digit, seven segment displays. Power Factor Corrected (PFC) universal input voltage allows maximum power to be delivered from an AC outlet without the user selecting the range. Fully rated current is delivered for either output voltage range of 135 VAC or 270 VAC over a standard frequency range of 45 to 500 Hz. It can be paralleled to provide extra power. A separate output-on switch controls power to the load. Remote voltage sense is standard. Transformer coupled output is protected against overvoltage and overcurrent. The unit is also protected against over temperature conditions. The front panel knobs (10 turn potentiometers) allow quick adjustment of voltage, current and frequency settings. Frequency and voltage can be programmed remotely using a 0 to 5V analog signal. LED’s indicate: output-on, voltage or current mode operation, fault and slave modes. Specifications. Power: 800 VA. Voltage ranges: 0 to 135 Vrms, 0 to 270 Vrms, user selectable. Voltage Accuracy: (>5VAC) ± 1% of range. Resolution: 0.1 Vrms. Total harmonic distortion: 0.25% typical <100Hz add 0.5%/100 Hz above 100 Hz. AC noise level (typical): <50 mVRMS. Amplitude stability: ±0.1% of full scale. Load regulation: ±0.1% of full scale voltage for a full resistive load to no load (<10 mVRMS typical, measured at point of sense). Line regulation: ±0.1% of full scale voltage for a ±10% line change from nominal line voltage (<5 mVRMS typical, measured at point of sense). Current: 6.0 ARMS (135 VAC Range), 3.0 ARMS (270 VAC Range). Current Accuracy ± 0.5% typical. Current Resolution: 0.1 ARMS. Frequency range: 45 to 500 Hz. Frequency Accuracy: ±0.5% typical. Frequency Resolution: 0.1 Hz.



 

Standard Calibration $315.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ELGAR CW801M. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your ELGAR CW801M CALIBRATION and/or ELGAR CW801M 0-135/270 Vrms, 3.0/6.0 ARMS Continuous Wave AC Power Source REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: