ELGAR CW801P CALIBRATION and ELGAR CW801P REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ELGAR CW801P Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ELGAR CW801P   Description / Specification:   Spec Sheet 
ELGAR CW801P 0-135/270 Vrms, 3.0/6.0 ARMS Continuous Wave AC Power Source

The Elgar CW 801P ContinuousWave (CW) AC power sources provides clean single phase power. The front panel has two bright four digit, seven segment displays. Power Factor Corrected (PFC) universal input voltage allows maximum power to be delivered from an AC outlet without the user selecting the range. Fully rated current is delivered for either output voltage range of 135 VAC or 270 VAC over a standard frequency range of 45 to 500 Hz. It can be paralleled to provide extra power. A separate output-on switch controls power to the load. Remote voltage sense is standard. Transformer coupled output is protected against overvoltage and overcurrent. The unit is also protected against over temperature conditions. Front panel encoder knobs allow programming of voltage, current and frequency settings. Programmed or measured values can be viewed on the two LED displays through push button selection. Menu push buttons enable setting system configuration including parallel or three phase operation. Specifications. Power: 800 VA. Voltage ranges: 0 to 135 Vrms, 0 to 270 Vrms, user selectable. Voltage Accuracy: (>5VAC) ±0.1% of range <100 Hz, ± 0.2% of range >100 Hz. Resolution: 0.1 Vrms. Total harmonic distortion: 0.25% typical <100Hz add 0.5%/100 Hz above 100 Hz. AC noise level (typical): <50 mVRMS. Amplitude stability: ±0.05% of full scale. Load regulation: ±0.1% of full scale voltage for a full resistive load to no load (<10 mVRMS typical, measured at point of sense). Line regulation: ±0.1% of full scale voltage for a ±10% line change from nominal line voltage (<5 mVRMS typical, measured at point of sense). Current: 6.0 ARMS (135 VAC Range), 3.0 ARMS (270 VAC Range). Current Accuracy ± 0.5% typical. Current Resolution: 0.01 ARMS. Frequency range: 45 to 500 Hz, 45 to 1000 Hz (option). Frequency Accuracy: ±0.02% typical. Frequency Resolution: 0.1 Hz, 0.01 Hz for remote programming.



 

Standard Calibration $315.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ELGAR CW801P. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your ELGAR CW801P CALIBRATION and/or ELGAR CW801P 0-135/270 Vrms, 3.0/6.0 ARMS Continuous Wave AC Power Source REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: