ELGAR 501SL CALIBRATION and ELGAR 501SL REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ELGAR 501SL Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ELGAR 501SL   Description / Specification:    
ELGAR 501SL 500 VA Frequency Changing Linear Power Source

The Elgar 501SL 500 VA solid-state frequency changing linear power source is ideal for general purpose test applications, as well as ATE systems and avionics testing. The output voltage, frequency, current, phase angle and other parameters of the SL Series Power source are controlled by Elgar's fixed, variable, or programmable plug-in oscillators (PIPs).
Specifications.
Number of Phases: 1.
Voltage Range: 0 to 65/130/260 VAC, rear panel and internal jumpers provide either 0-65/130 VAC or 0-130/260 VAC voltage ranges.
Rated Power Output: 750 VA.
Output Current: 11.5 A (0 to 65V), 5.8 A (0 to 130V), 2.9 A (0 to 260V).
Frequency range: 45 Hz to 5 KHz at full rated power.
Total Harmonic distortion: 0.6% max over full frequency range.
Line & load regulation: ±1% for 0-100% load change and ±10% input voltage variation cover full frequency range, adjustable to 0.1% for specific load conditions, better than ±0.25% for fixed frequency output.
Response Time: < 50 microseconds.
AC Noise Level: 70 dB below full output voltate with input grounded.
Metering: 0-300 VAC output voltmeter, ± 3% accuracy.



 

Standard Calibration $315.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ELGAR 501SL. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your ELGAR 501SL CALIBRATION and/or ELGAR 501SL 500 VA Frequency Changing Linear Power Source REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: