TEKTRONIX DPO71254C CALIBRATION and TEKTRONIX DPO71254C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DPO71254C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX DPO71254C   Description / Specification:   Spec Sheet 
TEKTRONIX DPO71254C 4 Ch 12.5 GHz Digital Phosphor Oscilloscope

The Tektronix DPO71254C with 4 analog channels has a high signal-to-noise ratio and low internal noise floor. It allows you to find the smallest anomalies affecting the DUT's performance. Bandwidth enhancement eliminates imperfections in frequency response all the way to the probe tip. User-selectable filters for each channel provide magnitude and phase correction for more accurate representation of extremely fast signals.

Specifications.
Analog channels: 4.
Analog bandwidth (user-selectable DSP enhance) (-3 dB): 12.5 GHz.
Hardware Analog Bandwidth (-3 dB): 12.5 GHz).
Rise time (typical): 32 ps (10% to 90%), 22 ps (20% to 80%).
Sample rate (1, 2 ch): 100 GS/s (maximum sample rate is 50 GS/s on digital channels routed to an analog channel through the iCapture™ analog mux).
Sample rate (3, 4 ch): 50 GS/s.
Record length, points (each channel, standard): 31.25 M.

Vertical system.
DC gain accuracy: ±2% (of reading).
Channel delay (typical): ≤10 ps for any two channels at equal V/div and coupling.
Signal-to-Noise ratio (typical): 34 dB.
Input coupling: DC (50 Ω), GND.
Input resistance selection: 50 Ω ±3%, 1 MΩ with TCA-1MEG adapter.
Input sensitivity range: 10 mV/div to 500 mV/div (100 mV to 5 V full scale).
Maximum input voltage, 50 Ω: <5.0 VRMS for ≥100 mV/div; 1.0 VRMS for <100 mV/div.

Horizontal system.
Channel-to-Channel: deskew range ±75 ns.
Time base accuracy: ±1.5 ppm initial accuracy, aging <1 ppm per year.
Time base delay time range: -5.0 ks to 1.0 ks.
Trigger jitter: <100 fsRMS (1 psRMS [typical] with enhanced triggering off).



 

Standard Calibration $390.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DPO71254C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX DPO71254C CALIBRATION and/or TEKTRONIX DPO71254C 4 Ch 12.5 GHz Digital Phosphor Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: