AMPROBE ACD-14 PLUS CALIBRATION and AMPROBE ACD-14 PLUS REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE ACD-14 PLUS Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE ACD-14 PLUS   Description / Specification:    
AMPROBE ACD-14 PLUS 600 Amp TRMS Clamp Type Meter

The Amprobe ACD-14 PLUS Digital Clamp Meter is the perfect choice for both HVAC and electrical applications due to its versatile set of features. Electricians will find it’s thin, light and versatile with thinner jaws than standard clamp meters (only 0.4”/10mm thick). Its ability to measure temperature, capacitance, and microamps are important features for HVAC technicians. The ACD-14 PLUS meter offers thinner jaws over standard clamp meters, allowing access to tight measurement areas and still accommodating conductors up to 25 mm.
Specifications / Features.

True-rms.
AC Voltage: 4.000 V, 40.00 V, 400.0 V, 600 V.
DC Voltage: 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V.
AC Current: 40.00 A, 400.0 A, 600 A.
Resistance: 400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ.
Capacitance: 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF, 3000 µF.
Frequency: 40 Hz to 400 Hz with Jaw, 10 Hz to 100 kHz with test leads.
Temperature: -4 °F to 999 °F (-20 °C to 537 °C).



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your AMPROBE ACD-14 PLUS CALIBRATION and/or AMPROBE ACD-14 PLUS 600 Amp TRMS Clamp Type Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: