BERKELEY NUCLEONICS CORPORATION 505-2C CALIBRATION and BERKELEY NUCLEONICS CORPORATION 505-2C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BERKELEY NUCLEONICS CORPORATION 505-2C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Pulse Generator?
Shop for Comparable Products on our
 used Pulse Generator page or new Pulse Generator page

 
For Sale New, List Price $2,175.00   BERKELEY NUCLEONICS CORPORATION 505-2C   Description / Specification:   Spec Sheet 
BERKELEY NUCLEONICS CORPORATION 505-2C Two Channel Pulse Generator

The BNC 505-2C Two Channel Pulse Generator has multiple modes of operation and 16 different edges in a single instrument. As a pulse generator it provides rate, delay, width, and output adjustability with each channel. As a digital delay generator, model 505 provides fine resolution, timing, and low jitter.
The outputs are synchronized to one another with coherence of 5 ns. A channel’s timing can be referenced to any other channel or to the zero delay point (To) The edges are adjustable in 100 ns steps. Channels can be selectively gated, enabled / disabled. Each channel possesses separate output level and polarity characteristics along with system level gating capability. Model 505 provides the ability to store custom parameter settings which are able to be recalled for later use.
Specifications.

Electrical Outputs: 2.

TIMING DELAYS AND WIDTHS.
Delay: 0 to 1000 seconds with 100 ns resolution.
Width: 100 ns to 1000 seconds with 10 ns resolution.
Accuracy: 10 ns + .0001 delay.
Time base: 50 MHz, 50 ppm crystal oscillator.
RMS jitter: < 2 ns.

EXTERNAL TRIGGER/GATE.
Rate: 0 to 2 MHz.
Insertion delay: < 250 ns.
Threshold: 200 mV - 15V.
Trigger slope: Rising or falling edge, selectable.
Gate: Active low or active high, selectable.
Impedance: 1000 ohms.

INTERNAL REP RATE GENERATOR.
Rate: 0.001 Hz to 2 MHz.
Accuracy: 5 ns + 0.0001 x period.
RMS jitter: < 500 ps.
OUTPUTS: Adjustable to 20 V.
IMPEDANCE: 50 ohm.

ADJUSTABLE AMPLITUDE.
Slew rate: > 0.2 V/ns.
Amplitude: 1V - 10V into 50 ohm load, 2 V - 20 V into high impedance.
Peak current: 150 mA per channel.
Average current: 200 mA average (total for all channels).
Polarity: Positive (active high) or Negative (low).

COMPUTER INTERFACE.
RS232: 4800, 9600, 19200 & 38400.
IEEE 4888: Standard.



 

Standard Calibration $390.00 *
*This is a Web introductory price for one calibration of the BERKELEY NUCLEONICS CORPORATION 505-2C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your BERKELEY NUCLEONICS CORPORATION 505-2C CALIBRATION and/or BERKELEY NUCLEONICS CORPORATION 505-2C Two Channel Pulse Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?