FLUKE 7526A CALIBRATION and FLUKE 7526A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 7526A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibration Standard? Shop for Comparable Products on our   new Calibration Standard page

 
   FLUKE 7526A   Description / Specification:    
FLUKE 7526A Precision Process Calibrator

The Fluke Calibration 7526A Precision Process Calibrator offers the best balance of economy and accuracy for benchtop calibration of pressure and temperature process instrumentation. Incorporating an isolated measurement channel, the 7526A lets you simultaneously source and measure voltage, current or resistance, making it easy to calibrate temperature and pressure transmitters, RTD and thermocouple readouts, pressure gauges, digital process simulators, data loggers, multimeters and more.
Specifications.

DC voltage, output.
Range / Absolute uncertainty, ± (output + V), 1 year / Resolution.
  0 mV to 100 mV / 30 ppm + 3 μV / 1 μV,
  0 V to 1 V / 30 ppm + 10 μV / 10 μV,
  0 V to 10 V / 30 ppm + 100 μV / 100 μV,
  0 V to 100 V / 30 ppm + 1 mV / 1 mV.

DC voltage, isolated input.
Range / Absolute uncertainty, ± (reading + V), 1 year / Resolution.
  0 V to 10 V / 100 ppm + 0.2 mV / 100 μV,
  10 V to 100 V / 100 ppm + 2.0 mV / 1 mV.

DC current, output.
Range / Absolute uncertainty, ± (reading + A), 1 year / Resolution.
  0 mA to 100 mA / 50 ppm + 1 μA / 1 μA.

DC current, isolated input.
Range / Absolute uncertainty, ± (reading + A), 1 year / Resolution.
  0 mA to 50 mA / 100 ppm + 1 μA / 1 μA,
  0 mA to 24 mA / 100 ppm + 1 μA / 1 μA.

Resistance, output.
Range / Absolute uncertainty, tcal ± 5 °C, ± ohms, 1 year / Resolution / Nominal current.
  5 Ω to 400 Ω / 0.015 / 0.001 Ω / 1 mA to 3 mA,
  5 Ω to 4 kΩ / 0.3 / 0.01 Ω / 100 μA to 1 mA.

Resistance, input.
Range / Absolute uncertainty, ± (reading + Ω), 1 year / Resolution.
  0 Ω to 400 Ω / 20 + 0.004 / 0.001 Ω,
  0 Ω to 4 kΩ / 20 + 0.04 / 0.01 Ω.

Sample thermocouple accuracy, input/output (does not include all available TC types).
TC type / Temperature range (°C) / Absolute uncertainty, tcal ±5 °C, ± (°C), 1 year.
  J / -210 to 1200 / 0.09.
  K / -250 to 1372 / 0.1,
  S / -50 to 1767 / 0.29,
  T / -250 to 400 / 0.11.

Sample RTD and thermistor, output (does not include all available RTD types).
RTD type / Temperature range (°C) / Absolute uncertainty, tcal ±5 °C, ± (°C), 1 year.
  Pt 385 100 Ω / -200 to 800 / 0.05,
  YSI 400 / 15 to 50 / 0.007.

Sample RTD and thermistor, output (does not include all available RTD types).
RTD type / Temperature range (°C) / Absolute uncertainty, tcal ±5 °C, ± (°C), 1 year.
  Pt 385 100 Ω / -80 to 100 / 0.020,
  Pt 385 100 Ω / 100 to 300 / 0.024,
  Pt 385 100 Ω / 300 to 800 / 0.026,
  YSI 400 / 15 to 50 / 0.007.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE 7526A CALIBRATION and/or FLUKE 7526A Precision Process Calibrator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: