MEGGER MIT40X-EN CALIBRATION and MEGGER MIT40X-EN REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the MEGGER MIT40X-EN Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   MEGGER MIT40X-EN   Description / Specification:    
MEGGER MIT40X-EN 10-100V Insulation and Continuity Tester

The Megger MIT40X-EN insulation and continuity tester offers those working in electrical engineering, the electrical supply industry and in maintenance, repair and servicing of industrial equipment and manufacturing processes a convenient test instrument.
Specifications.

Insulation.
Nominal test voltages: 10 V to 100 V variable (1 V increments).
Range full scale accuracy: All ranges ±2% ±2 digits up to 100 MΩ.
Short circuit current: 2 mA +0% -50%.
Terminal voltage: -0% +20% ±1 V (Ii <1 mA).
Test current on load: 1 mA at min. pass value of insulation specified in BS7671, HD384 and IEC364, EN61152-2, 2 mA max.
EN61557 operating range: 0,10 MΩ to 1,00 GΩ.
Leakage current range: 10 μA to 2000 μA.
Leakage current: 10% ±3 digits.
Voltage display: 3% ±3 digits ±0.5% of rated voltage.
Polarization Index (PI): 10 min / 1 minute ratio.
Dielectric absorption Ratio (DAR): 60 sec / 30 sec ratio.

Continuity.
EN61557 operating range: 0, 01 Ω to 99, 9 Ω (0 to 100 Ω on analogue scale).
Accuracy: ± 2% ± 2 digits (0 to 100 Ω).
Open circuit voltage: 5 V ± 1 V.
Test current: 205 mA (±5 mA) (0.01 Ω to 9.99 Ω), 20 mA (±1 mA) (10.0 Ω to 99.9 Ω).
Zero offset at probe tips: 0, 10 Ω typical.
Lead resistance zeroing: Up to 9, 99 Ω.
Buzzer: Variable limit 1 Ω, 2 Ω, 5 Ω, 10 Ω, 20 Ω.

Resistance.
EN61557 operating range: 0, 01 k Ω to 1000 k Ω (0 to 1 M Ω on analogue scale).
Accuracy: ±3% up to 50 k Ω then ±5% ±2 digits.
Open circuit voltage: 5 V ±1 V.
Short circuit current: 1.5 mA ±0.2 mA.

Voltage range.
0 to 600 V d.c. ± 2% ± 2 digits.
10 mV to 600 V TRMS sinusoidal (40 - 400 Hz) ±2% ±2 digits.

Default Voltmeter.
Operates at >25 volts a.c. or d.c., on any range except OFF.
Frequency: 15-400Hz (15Hz - 99,9Hz) ±0.5% ±1 digit (100Hz to 400Hz).



 

Standard Calibration $210.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the MEGGER MIT40X-EN. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your MEGGER MIT40X-EN CALIBRATION and/or MEGGER MIT40X-EN 10-100V Insulation and Continuity Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: