BOONTON PIM 31-F02 CALIBRATION and BOONTON PIM 31-F02 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BOONTON PIM 31-F02 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Cellular Test Set? Shop for Comparable Products on our   new Cellular Test Set page

 
   BOONTON PIM 31-F02   Description / Specification:    
BOONTON PIM 31-F02 TX 925-960, RX 880-915 MHz Pim Analyzer

The Boonton PIM31-F02 test system is a precision analyzer for passive intermodulation generated in RF paths, components and assemblies. It emulates a base station radio by providing two signals, up to 20W each, thus following the IEC62037 standard for PIM testing. The frequencies of these carriers are variable within the band of the analyzer, allowing PIM 31 operators to select the optimal frequencies for their wireless systems.

Specifications.
TX Band: 925-960 MHz.
RX Band: 880-915 MHz.
PIM test: Single port reflection.

Carrier Power.
Carrier Power Adjustable Level: +20 to +44 dBm.
Carrier Power Resolution/Accuracy: 0.25 dB / ±0.35 dB.
Frequency Increment: 200 kHz.
Frequency Accuracy (typical): 2 ppm.
Frequency Tuning Lock Time (typical): 1 MS.
Reverse Power Protection (Include ON/OFF Function): 43 dBm / 5 sec Receiver.

Receiver Specifications.
Reverse IM: -132 dBm / -175 dBc.
Average Noise Floor: -138 dBm (1.2 k filter).
Dynamic Range (typical): 96 dB (reference -90 dBm).
Effective IF Bandwidth: 300 Hz, 600 Hz 1.2k, 2.4k, 5k, 10k, 12k, 15k, 25k, 50 kHz.
Operational Input Power: -45 dBm RMS.
Input Power without damage: -10 dBm max.
PIM Measurement Accuracy: ±2 dB for 2 x 43 dBm.

System.
RF Connector: DIN 7/16
User Interface Display: 7” TFT with touch screen display.



 

Standard Calibration $890.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BOONTON PIM 31-F02. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Accuracy
Accuracy is the degree of closeness of measurements of a quantity to that quantity's actual (true) value.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Receiver Sensitivity
Receiver Sensitivity is the optical power required by a receiver for low error signal transmission. In the case of digital signal transmission, the mean optical power is usually quoted in Watts or dBm (decibels referred to 1 milliwatt).


Please contact us for your BOONTON PIM 31-F02 CALIBRATION and/or BOONTON PIM 31-F02 TX 925-960, RX 880-915 MHz Pim Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: