MEGGER MIT210 CALIBRATION and MEGGER MIT210 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the MEGGER MIT210 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   MEGGER MIT210   Description / Specification:    
MEGGER MIT210 1000V Insulation and Continuity Tester

The Megger MIT210 insulation and continuity tester is used for installing electrical installations, on both domestic and industrial systems, as well as within site maintenance and service departments. It is also ideal for testing domestic appliances, power tools, transformers, motors, generators, switchgear, electrical panels etc., as well as fixed electrical wiring systems.
Specifications.

Insulation Range.
Nominal test voltages: 1000 V (dc).
Measurement range: 10 kΩ - 1000 MΩ on all ranges, Terminal voltage on open circuit (dc) -0 % +25 % of rated voltage.
Test current on load: >1 mA at minimum pass values of insulation as specified in BS 7671, HD 384, IEC 364 and VDE 0413 part 1.

Continuity Range.
Measuring range: 0.01 Ω - 100.0 Ω (0 -50 Ω on analog scale).
Open circuit voltage: 5 V ±1 V.
Short circuit current: 205 mA +10 mA -5 mA >18 mA (10 - 100 Ω).
Accuracy (at 20° C): ±0.01 Ω to 9.99 Ω ± 3 % ±2 digits, 10.0 Ω to 99.9 Ω ± 5 % ±2 digits.
Zero offset adjust: 0 to 9.99 Ω.
Continuity buzzer: Operates at < 2 Ω.
Default voltmeter: >25 V a.c. or d.c. is applied display will operate as a voltmeter.

Voltmeter.
Range: 25 V to 600 V @ 50/60 Hz & dc.
Accuracy: 25 V to 450 V ac/dc ± 1% ± 1 digit, 450 V to 600 V ac ± 2% ± 1 digit.



 

Standard Calibration $210.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the MEGGER MIT210. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your MEGGER MIT210 CALIBRATION and/or MEGGER MIT210 1000V Insulation and Continuity Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: