INSTEK GPT-9902A CALIBRATION and INSTEK GPT-9902A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GPT-9902A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   INSTEK GPT-9902A   Description / Specification:    
INSTEK GPT-9902A 5KV AC, 6KV DC Withstanding Voltage Tester

The GW Instek GPT- 9902A is capable of performing both AC and DC withstanding tests needed for the compliance of the safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety regulations. The output voltage is automatically cut off (within 150μs) upon the detection of an abnormal output voltage or a trip of current limits during test to protect the operator from hazardous injury. It automatically discharges the DUT after each test to eliminate excessive voltage that remains on the DUT.
Specifications.

AC Withstanding.
Output-Voltage Range: 0.050kV to 5.000kV ac.
Output-Voltage Resolution: 2V/step.
Output-Voltage Accuracy: ± (1% of setting +5V) [no load].
Maximum Rated Load: 500 VA (5kV/100mA).
Maximum Rated Current: 100mA (0.5kV < V ≤ 5kV), 10 mA (0.05kV ≤ V≤ 0.5kV).
Output-Voltage Waveform: Sine wave.
Output-Voltage Frequency: 50 Hz / 60 Hz selectable.
Voltmeter Accuracy: ± (1% of reading+ 5V).
Current Measurement Range: 0.001 mA to 100.0 mA.
Current Best Resolution: 0.001mA / 0.01mA / 0.1mA.
AC Current Measurement Accuracy: ±(1.5% of reading +30 counts) when HISET < 1.11mA, ±(1.5% of reading +3 counts) when HISET ≥ 1.11mA.
ARC Detect: Yes.
RAMP (Ramp-Up Time): 0.1 to 999.9s.
TIMER (Test Time): OFF, 0.5s to 999.9s.
Sweep Function: Yes.
GND: ON/OFF.

DC Withstanding.
Output-Voltage Range: 0.050kV to 6.000kV dc.
Output-Voltage Resolution: 2V/step.
Output-Voltage Accuracy: ± (1% of setting +5V) [no load].
Maximum Rated Load: 100W (5kV/20mA).
Maximum Rated Current: 20mA (0.5kV < V ≤ 6kV), 2mA (0. 05kV ≤ V≤ 0.5kV).
Voltmeter Accuracy: ± (1% of reading+ 5V).
Current Measurement Range: 0.001mA to 20.0mA.
Current Best Resolution: 0.001mA / 0.01mA / 0.1mA.
DC Current Measurement Accuracy: ±(1.5% of reading +30 counts) when HISET < 1.11mA, ±(1.5% of reading +3 counts) when HISET ≥ 1.11mA.
ARC Detect: Yes.
RAMP (Ramp-Up Time): 0.1 to 999.9s.
TIMER (Test Time): OFF, 0.5s to 999.9s.
Sweep Function: Yes.
GND: ON/OFF.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GPT-9902A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your INSTEK GPT-9902A CALIBRATION and/or INSTEK GPT-9902A 5KV AC, 6KV DC Withstanding Voltage Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: