A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GPT-9904 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   INSTEK GPT-9904   Description / Specification:    
INSTEK GPT-9904 5KV AC, 6KV DC Withstanding Voltage / IR / Ground Tester

The GW Instek GPT- 9904 is capable of performing AC withstanding, DC withstanding, insulation resistance and ground bond tests needed for the compliance of the safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety regulations. The output voltage is automatically cut off (within 150μs) upon the detection of an abnormal output voltage or a trip of current limits during test to protect the operator from hazardous injury. It automatically discharges the DUT after each test to eliminate excessive voltage that remains on the DUT.
Specifications.

AC Withstanding.
Output-Voltage Range: 0.050kV to 5.000kV ac.
Output-Voltage Resolution: 2V/step.
Output-Voltage Accuracy: ± (1% of setting +5V) [no load].
Maximum Rated Load: 500 VA (5kV/100mA).
Maximum Rated Current: 100mA (0.5kV < V ≤ 5kV), 10 mA (0.05kV ≤ V≤ 0.5kV).
Output-Voltage Waveform: Sine wave.
Output-Voltage Frequency: 50 Hz / 60 Hz selectable.
Voltmeter Accuracy: ± (1% of reading+ 5V).
Current Measurement Range: 0.001 mA to 100.0 mA.
Current Best Resolution: 0.001mA / 0.01mA / 0.1mA.
AC Current Measurement Accuracy: ±(1.5% of reading +30 counts) when HISET < 1.11mA, ±(1.5% of reading +3 counts) when HISET ≥ 1.11mA.
ARC Detect: Yes.
RAMP (Ramp-Up Time): 0.1 to 999.9s.
TIMER (Test Time): OFF, 0.5s to 999.9s.
Sweep Function: Yes.
GND: ON/OFF.

DC Withstanding.
Output-Voltage Range: 0.050kV to 6.000kV dc.
Output-Voltage Resolution: 2V/step.
Output-Voltage Accuracy: ± (1% of setting +5V) [no load].
Maximum Rated Load: 100W (5kV/20mA).
Maximum Rated Current: 20mA (0.5kV < V ≤ 6kV), 2mA (0. 05kV ≤ V≤ 0.5kV).
Voltmeter Accuracy: ± (1% of reading+ 5V).
Current Measurement Range: 0.001mA to 20.0mA.
Current Best Resolution: 0.001mA / 0.01mA / 0.1mA.
DC Current Measurement Accuracy: ±(1.5% of reading +30 counts) when HISET < 1.11mA, ±(1.5% of reading +3 counts) when HISET ≥ 1.11mA.
ARC Detect: Yes.
RAMP (Ramp-Up Time): 0.1 to 999.9s.
TIMER (Test Time): OFF, 0.5s to 999.9s.
Sweep Function: Yes.
GND: ON/OFF.

Insulation Resistance.
Output-Voltage: 50V to 1000V dc.
Output-Voltage Resolution: 50V/step.
Output-Voltage Accuracy: ± (1% of setting +5V) [no load].
Resistance Measurement Range: 0.001G Ω to 50.00G Ω.

Ground Bond.
Output-Current Range: 03.00A to 32.00A ac.
Output-Current Resolution: 0.01A.
Output-Current Accuracy: 3A ≤I ≤8A ± (1% of setting +0.2A), 8A < I ≤32A ± (1% of setting +0.05A).
Test-Voltage: 6Vac max (open circuit).
Test-Voltage Frequency: 50 Hz / 60 Hz selectable.
Resistance Measurement Range: 10 mΩ to 650.0 mΩ.
Resistance Measurement Resolution: 0.1 mΩ.
Resistance Measurement Accuracy: ± (1% of reading +2 mΩ).



 

Standard Calibration $265.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GPT-9904. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your INSTEK GPT-9904 CALIBRATION and/or INSTEK GPT-9904 5KV AC, 6KV DC Withstanding Voltage / IR / Ground Tester REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: