MEGGER MIT320 CALIBRATION and MEGGER MIT320 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the MEGGER MIT320 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   MEGGER MIT320   Description / Specification:    
MEGGER MIT320 250, 500, 1000 V Insulation Tester

The Megger MIT320 features the popular Megger digital/analogue display. Large 20mm high characters provide very clear readout, combined with an analogue arc for the feel of an analogue instrument, with a true analogue response.
Specifications

Insulation ranges
Nominal Test Voltage: 1000 V, 500 V, 250 V (d.c.).
Measuring Range: 10 kΩ - 999 MΩ on all ranges.
Short Circuit Current: 1.5 mA nominal.
Test Current on Load: 1 mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364).
Accuracy (at 20 °C): ±3%, ±2 digits up to 10 MΩ, ±5% up to 100 MΩ, ±30% up to full scale

Continuity ranges
Measuring Range: 0,01 Ω - 99,9 Ω (0 -50 Ω on analogue scale).
Open Circuit Voltage: 5 V ±1 V.
Short Circuit Current: 205 mA +10 mA -5 mA.
Accuracy (at 20 °C): ±3% ±2 digits.
Measuring range: 0 - 2/20/200/2 kΩ.
Open circuit voltage: 1.5 V +/-0.5 V.
Zero Offset Adjust: 0 - 9 Ω.
Continuity Buzzer: Adjustable 1 Ω to 20 Ω.

Resistance range
Measuring Range: 10 Ω - 1 MΩ.
Open Circuit Voltage: 5 V.
Short Circuit Current: 1.5 mA.
Accuracy (at 20° C): ±5% ±2 digits up to 100 kΩ.

Default voltmeter all modes except off: >25 V a.c. or d.c. is applied display will operate as a voltmeter.
Test inhibit: If more than 50 volts is detected, testing will be inhibited.



 

Standard Calibration $270.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the MEGGER MIT320. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your MEGGER MIT320 CALIBRATION and/or MEGGER MIT320 250, 500, 1000 V Insulation Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: