TRANSMILLE EA002 CALIBRATION and TRANSMILLE EA002 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TRANSMILLE EA002 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibration Standard? Shop for Comparable Products on our   new Calibration Standard page

 
For Sale New, List Price $1,372.00   TRANSMILLE EA002   Description / Specification:    
TRANSMILLE EA002 Clamp Coil Adapter

The Transmille EA002 Clamp Coil Adapter is designed for the calibration of both wound (AC only) & Magnetic field (hall effect) AC/DC clamp meters the current coil offers several unique features built in a robust construction. The coil is designed to immerse both jaws of the clamp meter in the magnetic field while allowing the ‘gap’ or opening where magnetic flux will escape to protrude through the coil and stay out of the strongest part of the field. This makes the reading less dependent on the position of the clamp within the coil and also the quality of the jaw closing, allowing greater confidence in the calibration.
Specifications.

Connection to Calibrator: Via supplied 4mm to 4mm connection leads (x2) to 3000 series current terminals.
Coil Configuration: 2 Turn (LHS), 10 Turn (RHS), 50 Turn (CENTRE).
Coil Type: High accuracy balanced configuration.
Min. internal jaw dimensions: 10mm (2 Turn & 10 Turn), 25mm (50 Turn).
Maximum Current: 30A.
Maximum RMS voltage: 4V.
Frequency Range: DC to 500Hz.

2 Turn Coil Accuracy (Input 0 to 30A : Freq. DC - 30Hz to 60Hz : Effective Output 0 to 60A).
Effective accuracy - Coil only (wound clamps, 90 Day Rel.) 0.35% + 0.008A.
Effective accuracy - Coil only (hall effect clamps, 90 Day Rel.) 0.48% + 0.07A.

10 Turn Coil Accuracy (Input 0 to 30A : Freq. DC - 30Hz to 60Hz : Effective Output 0 to 300A).
Effective accuracy - Coil only (wound clamps, 90 Day Rel.) 0.41% + 0.01A.
Effective accuracy - Coil only (hall effect clamps, 90 Day Rel.) 0.59% + 0.11A.

50 Turn Coil Accuracy (Input 0 to 30A : Freq. DC - 30Hz to 60Hz : Effective Output 0 to 1500A).
Effective accuracy - Coil only (wound clamps, 90 Day Rel.) 0.24% + 0.04A.
Effective accuracy - Coil only (hall effect clamps, 90 Day Rel.) 0.45% + 0.42A.



 

Standard Calibration $865.00 *
*This is a Web introductory price for one calibration of the TRANSMILLE EA002. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your TRANSMILLE EA002 CALIBRATION and/or TRANSMILLE EA002 Clamp Coil Adapter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: