SLAUGHTER 2935 CALIBRATION and SLAUGHTER 2935 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SLAUGHTER 2935 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   SLAUGHTER 2935   Description / Specification:    
SLAUGHTER 2935 5KV AC, 6KV DC Withstanding Voltage Tester

The Slaughter 2935 Hipot tester was designed to provide safe, reliable, and cost-effective electrical safety testing. It complies with agency requirements from such agencies as UL, TÜV, CSA, VDE, and IEC.
Specifications.

Dielectric Withstand Test Mode.
Input Voltage: 115/230V selectable, ± 15% variation 47 - 63Hz.
Output Rating: AC 0 - 5000V, 2V/step, 12mA, DC 0 - 6000V, 2V/step, 5mA.
Output Regulation: ± (1% of output + 5V).
Voltage Setting: 0V - Max output rating, 10 volt step.
Voltage Setting Accuracy: ± (2% of Setting + 5V) (relative to displayed output).
Output Frequency: DC and 50/60Hz selectable.
Ripple: < 5% at 6KVDC/5mA.
Wave Form Sinewave Distortion : < 2% THD.
Dwell Time Setting: 0 & 0.2 - 999.9 seconds, 0.1 second/step “0” for continuous running.
Ramp Time Setting: 0 & 0.2 - 999.9 seconds, 0.1 second/step 0 ramp setting = 0.1 seconds fixed ramp.
Failure Settings AC Mode;
  High limit: 0.10 - 12.00mA, 0.01mA/step.
  Low limit: 0.00, 0.10 - 12.00mA, 0.01mA/step (0 = OFF).
  Accuracy: ± (2% of setting + 0.02mA).
Failure Settings DC Mode;
  High limit: 0.02 - 5.00mA, 0.01mA/step.
  Low limit: 0.00, 0.02 - 5.00mA, 0.01mA/step (0 = OFF).
  Accuracy: ± (2% of setting + 0.02mA).
Discharge Time: ≤ 300ms.
Ground Continuity Check;
  Current: DC 0.1A ± 0.01A, fixed.
  Maximum ground resistance: 1Ω ± 0.1Ω, fixed.



 

Standard Calibration $635.00 *
*This is a Web introductory price for one calibration of the SLAUGHTER 2935. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your SLAUGHTER 2935 CALIBRATION and/or SLAUGHTER 2935 5KV AC, 6KV DC Withstanding Voltage Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: