AIM-TTI PSA2702 CALIBRATION and AIM-TTI PSA2702 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AIM-TTI PSA2702 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   AIM-TTI PSA2702   Description / Specification:    
AIM-TTI PSA2702 1MHz to 2.7 GHz Handheld RF Spectrum Analyzer

The AIM-TTI Instruments PSA2702 is a fully portable RF spectrum analyzer that incorporates a high resolution color TFT touch screen. It is sufficiently small and lightweight to be operated as a true handheld instrument and has a battery life of more than eight hours from each charge. The on-screen amplitude range is 85 dB with a reference level of -20dBm or 0dBm. Amplitudes can alternatively be displayed in dBμV. Vertical magnification down to 1dB/div can be selected. Average noise floor is better than -95dBm at -20dBm reference level and 15 kHz RBW (video filter on).
Specifications.

Frequency Measurement.

Frequency Span;
Frequency Range: 1 MHz to 2700 MHz in one range.
Setting Modes: Center frequency plus Span, or Start frequency plus Stop frequency.
Maximum Span: 2699 MHz (1 MHz to 2700 MHz).
Minimum Span: 270 kHz, or Zero Span with demodulation.
Setting Resolution: 1 kHz at any frequency.
Setting Accuracy: Reference Frequency Accuracy for Start, Stop & Center (Zero-Span) frequencies.

Reference Frequency Accuracy;
Initial Accuracy: Better than ± 10 ppm at 20°C.
Stability: Better than ± 10 ppm over 10°C to 30°C.
Ageing: Better than ± 3 ppm per year.

Phase Noise;
Phase Noise: Typically -90dBc/Hz at 100kHz offset at 500MHz.

Resolution Bandwidth;
RBW: Selectable as 1 MHz, 280 kHz or 15 kHz.
Video Filtering: Selectable On or Off.

Amplitude Measurement (Level).

Amplitude Range;
Display Range: 85 dB.
Measurement Units: dBm or dBμV (dB milliwatts or dB micro volts).
Reference Level: Selectable as -20 dBm or 0dBm (87 dBμV or 107 dBμV).

Amplitude Accuracy;
Ref. Level Accuracy: Better than ± 1 dB at 50MHz at 10dB below ref. level (20°C ± 5°C)
Level Flatness: Better than ± 1.5 dB relative to 50MHz over 1MHz to 2700MHz.
Amplitude Linearity: Better than ± 1 dB over 50dB range down from reference level.

Noise Floor;
Noise Floor: Better than -95 dBm average displayed noise floor for F > 3MHz (reference level = -20 dBm, RBW = 15 kHz, video filter On).



 

Standard Calibration $565.00 *
*This is a Web introductory price for one calibration of the AIM-TTI PSA2702. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your AIM-TTI PSA2702 CALIBRATION and/or AIM-TTI PSA2702 1MHz to 2.7 GHz Handheld RF Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: