KEYSIGHT U1191A CALIBRATION and KEYSIGHT U1191A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT U1191A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   KEYSIGHT U1191A   Description / Specification:    
KEYSIGHT U1191A 400A Handheld Clamp Multimeter

The Keysight U1191A clamp meter has a unique wire separator allows you to effortlessly isolate and perform measure­ments on individual wires in a bundle. For improved visibility when making measurements, these clamp meters also come with an easily activated built-in LED flashlight that illuminates the test area.
Specifications.

Display: 6,000 counts.
RMS method: Average responding.

DC Voltage;
Range: 600 V, 0.1 V (Resolution), 0.5% + 3 (Accuracy).
Resistance;
Range: 600 Ω, 0.1 Ω (Resolution), 0.8% + 5 (Accuracy).
Range: 6 kΩ, 0.001 kΩ (Resolution), 0.8% + 3 (Accuracy).
Diode;
Range: 1.5 V, 0.001 V (Resolution), 1.0% + 3 (Accuracy).
AC Voltage;
Range: 600 V, 0.1 V (Resolution), 1.2% + 5 (Accuracy).
AC Current;
Range: 400 A, 0.1 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT U1191A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your KEYSIGHT U1191A CALIBRATION and/or KEYSIGHT U1191A 400A Handheld Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?