KEYSIGHT U1191A CALIBRATION and KEYSIGHT U1191A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT U1191A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   KEYSIGHT U1191A   Description / Specification:    
KEYSIGHT U1191A 400A Handheld Clamp Multimeter

The Keysight U1191A clamp meter has a unique wire separator allows you to effortlessly isolate and perform measure­ments on individual wires in a bundle. For improved visibility when making measurements, these clamp meters also come with an easily activated built-in LED flashlight that illuminates the test area.
Specifications.

Display: 6,000 counts.
RMS method: Average responding.

DC Voltage;
Range: 600 V, 0.1 V (Resolution), 0.5% + 3 (Accuracy).
Resistance;
Range: 600 Ω, 0.1 Ω (Resolution), 0.8% + 5 (Accuracy).
Range: 6 kΩ, 0.001 kΩ (Resolution), 0.8% + 3 (Accuracy).
Diode;
Range: 1.5 V, 0.001 V (Resolution), 1.0% + 3 (Accuracy).
AC Voltage;
Range: 600 V, 0.1 V (Resolution), 1.2% + 5 (Accuracy).
AC Current;
Range: 400 A, 0.1 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT U1191A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your KEYSIGHT U1191A CALIBRATION and/or KEYSIGHT U1191A 400A Handheld Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?