KEYSIGHT N8487A CALIBRATION and KEYSIGHT N8487A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT N8487A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   KEYSIGHT N8487A   Description / Specification:    
KEYSIGHT N8487A 50 GHz Thermocouple Power Sensor

The Keysight N8487A Thermocouple Power Sensor is the replacement solution for 8480 Series Power Sensors. The new power sensor is integrated with EEPROM feature, which allows users to calibrate the power sensors without manually entering the calibration factors to the power meter. By comparing to legacy 8480 Series Power Sensors, there are tremendous improvements such as wider dynamic range and frequency range, better accuracy, linearity, repeatability, and SWR.
Specifications.

Frequency range: 50 MHz to 50 GHz.
Dynamic power range: -35 to +20 dBm.
Damage level (average power): +25 dBm.
Damage level (peak power): 15 W/2 µs.
Maximum SWR 25 °C ± 10 °C:
  1.08 (50 MHz to 100 MHz),
  1.05 (100 MHz to 2 GHZ),
  1.10 (2 GHz to 12.4 GHz),
  1.16 (12.4 GHz to 18 GHz),
  1.22 (18 GHZ to 26.5 GHz),
  1.30 (26.5 GHz to 40 GHz),
  1.34 (40 GHz to 50 GHz).
Linearity (25 °C ± 10 °C): ±0.52% (-1 to < +15 dBm), ±0.80% (+15 to +20 dBm).
Connector: 2.4 mm (male).

Option
CFT, N8487A sensor without the calibration factor table stored in the EEPROM.



 

Standard Calibration $415.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT N8487A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your KEYSIGHT N8487A CALIBRATION and/or KEYSIGHT N8487A 50 GHz Thermocouple Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: