A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT N5182B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   KEYSIGHT N5182B   Description / Specification:    
KEYSIGHT N5182B 3/6 GHz MXG X-Series Vector Signal Generator

The Keysight N5182B MXG X-Series Vector Signal Generator is used to test radar receiver sensitivity, characterize ADC or mixer SNR, or find receiver out-of-band rejection capability. You’ll get excellent results with industry-leading phase noise of -146 dBm at 1 GHz and spurious performance of -96 dBc at 1 GHz. With EVM of less than 0.4 percent (802.11ac and LTE) and factory-equalized 160 MHz RF bandwidth with flatness of less than ± 0.2 dB, the MXG enables testing and characterization of multicarrier power amplifiers or wideband receivers and components, such as those used in 802.11ac WLAN designs.
Specifications.

Frequency Range: 9 kHz (5 MHz IQ mode) to 3 GHz (Option 503), 9 kHz (5 MHz IQ mode) to 6 GHz (Option 506).
Resolution: 0.001 Hz.
Phase offset: Adjustable in nominal 0.1 ° increments.
Output Settable range: +30 to -144 dBm.
Resolution: 0.01 dB.
Step attenuator: 0 to 130 dB in 5 dB steps electronic type.
Connector: Type N 50 ohm, nominal.
Phase noise @ 1 GHz, 20 kHz offset: -146 dBc/Hz.
Spurious @ 1 GHz: -96 dBc.
Output power @ 1 GHz: +27 dBm.
ACPR W-CDMA 64 DPCH (vector): -73 dBc.
EVM 802.11ac/LTE (vector): 0.4 percent.
Bandwidth (vector): 160 MHz.
Arbitrary waveform memory (vector): 1024 MSa.
Interfaces: GPIB IEEE-488.2, 1987 with listen and talk, LAN 1000BaseT LAN interface, LXI class C compliant, USB Version 2.0.

Options.
503 - 9 kHz to 3 GHz.
506 - 9 kHz to 6 GHz.
006 - Instrument security and removable memory card.
1EA - High output power.
656 - ARB baseband generator (80 MHz RF bandwidth, 64 Msa).
657 - Upgrade baseband generator to 160 MHz RF bandwidth.
660 - Upgrade baseband generator with real-time capability.
UNT - AM, FM, phase modulation.
UNV - Enhanced dynamic range.
UNW - Narrow pulse modulation.
UNX - Low phase noise.
UNY - Enhanced low phase noise.
UNZ - Fast switching.



 

Standard Calibration $500.00 *
*This is a Web introductory price for one calibration of the KEYSIGHT N5182B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your KEYSIGHT N5182B CALIBRATION and/or KEYSIGHT N5182B 3/6 GHz MXG X-Series Vector Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: