FLUKE 5522A CALIBRATION and FLUKE 5522A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5522A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 5522A   Description / Specification:    
FLUKE 5522A Multi-Product Calibrator

The Fluke 5522A Multi-Product Calibrator addresses a wide calibration workload and comes with internal and external protection features that protect it against damage and make it easier to transport for on-site or mobile calibration. It can also be fully automated with MET/CAL® Plus Calibration Management Software. The 5522A is the ideal calibrator for metrology professionals who need to calibrate many different types of electronic equipment and want a transportable instrument that offers them a high return on investment.
The Fluke 5522A sources direct voltage and current, alternating voltage and current with multiple waveforms and harmonics, two simultaneous voltage outputs or voltage and current to simulate dc and ac power with phase control, resistance, capacitance, thermocouples and RTDs. It can also measure thermocouple temperature and pressure using one of 29 Fluke 700 Series pressure modules.
Specifications.

Direct volts: 0 to ± 1020 V.
Direct current: 0 to 20.5 A.
Alternating volts: 1 mV to 1020 V, 10 Hz to 500 kHz.
Volt/Hertz: 1000 V@ 10 kHz/330 V@100 kHz.
Alternating current: 29 μA to 20.5 A, 10 Hz to 30 kHz.
Waveforms: Sine, square, triangle, truncated sine.
Resistance: 0 Ω to 1100 MΩ.
Capacitance: 220 pF to 110 mF.
Power (phantom loads): 20.9 kW.
Phase control: 0.01°.
Thermocouple (source and measure temperature): B, C, E, J, K, L, N, R, S, T, U; 10 μV/°C and 1 mV/°C.
RTD (source temperature):
  Pt 385-100 Ω, Pt 3926-100 Ω, Pt 3916-100 Ω,
  Pt 385-200 Ω, Pt 385-500 Ω, Pt385 1000 Ω,
  PtNi 385-120 Ω, (Ni120), Cu 427 10 Ω.
Frequency uncertainty: <2.5 ppm.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE 5522A CALIBRATION and/or FLUKE 5522A Multi-Product Calibrator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: