A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5730A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 5730A   Description / Specification:    
FLUKE 5730A High Performance Multifunction Calibrator

The Fluke 5730A High Performance Multifunction Calibrator is designed for calibration professionals who require the most accurate dc/lf signals available in a multifunction calibrator, as well as those who simply want the best calibrator available. Metrologist’s in national laboratories, the military, third party calibration laboratories, and corporate users with high-end workload will value the performance and reliability of the 5730A. All 5730A calibrators are traceable to international standards and are produced in the factory with ISO/IEC 17025 accredited calibrations. Specifications are stated to the standard Fluke Calibration 99 % confidence level (as well as 95 % confidence level) to support easy measurement comparisons according to international quality standards. Specifications are absolute and include the uncertainty of the calibration standards used.
Specifications.

Voltage DC;
  Range: 0 to ±1100 V
  Best 1 Year, 95% Specification: 3.5 ppm + 2.5 µV.
Voltage AC;
  Range: 22 µV to 1100V, 10 Hz to 1 MHz
  Best 1 Year, 95% Specification: 42 ppm + 8 µV.
Resistance;
  Range: 0 to 100 MΩ, 18 values in x1 and x1.9
  Best 1 Year, 95% Specification: 6.5 ppm.
Current DC;
  Range: 0 to ±2.2A (0 to ±11A with 5725A; 0 to ±100 A with 52120A)
  Best 1 Year, 95% Specification: 35 ppm + 7 nA.
Current AC;
  Range: 9 µA to 2.2A, 10 Hz to 10 kHz (9 µA to ±11A with 5725A; 9 µA to ± 120 A with 52120A)
  Best 1 Year, 95% Specification: 103 ppm + 8 nA.
Wideband ac Voltage option;
  Range: 300 µV to 3.5V, 10 Hz to 50 MHz
  Best 1 Year, 99% Specification: 0.4% + 500 µV.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your FLUKE 5730A CALIBRATION and/or FLUKE 5730A High Performance Multifunction Calibrator REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: