A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5080A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 5080A   Description / Specification:    
FLUKE 5080A Multi-Product Calibrator

The Fluke 5080A calibrator calibrates your analog workload accurately and reliably, thanks to its high voltage and current compliance. With maximum burden up to 800 mA for voltage, and maximum compliance voltage up to 50 V for current, the 5080A can drive a wide range of analog meters. The 5080A calibrator’s innovative protection circuitry prevents it from being damaged by reversed input voltage, so you can use it with confidence day after day.
Specifications.

Voltage DC;
  Range: 0 to ±1020 V
  Best 1 Year Specification: ±0.01% of setting.
Current DC;
  Range: 0 to ±20.5A
  Best 1 Year Specification: ±0.05% of setting.
Resistance;
  Range: 0 to 190 MΩ, 19 values in x1 and x1.9
  Best 1 Year Specification: ±0.025% of setting.
Voltage AC;
  Range: 1 mV to 1020V, 45Hz to 1 kHz, Sine
  Best 1 Year Specification: ±0.1% of setting.
Current AC;
  Range: 29 mA to 20.5A, 45 Hz to 1 kHz, Sine
  Best 1 Year Specification: ±0.1% of setting.
DC Power;
  Range: 10.9 mW to 20.5 kW
  Best 1 Year Specification: ±0.11% of setting.
AC Power;
  Range: 10.9 mW to 20.5 kW, 45-65 Hz, PF=1
  Best 1 Year Specification: ±0.36% of setting.
Phase;
  Range: 0 to ± 179.99°, 45 Hz to 1 kHz
  Best 1 Year Specification: ±0.25° of setting.
Frequency;
  Range: 45 Hz to 1 kHz
  Best 1 Year Specification: ±50 ppm of setting.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your FLUKE 5080A CALIBRATION and/or FLUKE 5080A Multi-Product Calibrator REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: