VIAVI CA5000 CALIBRATION and VIAVI CA5000 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the VIAVI CA5000 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Cellular Test Set? Shop for Comparable Products on our   new Cellular Test Set page

 
   VIAVI CA5000   Description / Specification:    
VIAVI CA5000 CellAdvisor 5G

The VIAVI CA5000 CellAdvisorTM 5G is the ideal field portable solution to validate 5G radio access. It has a Portable Real-Time Spectrum Analyzer; NR FR1 up to 6 GHz, NR FR1 up to 6 GHz and FR2 up to 40 GHz, 9 kHz to 18.5 GHz. With support for 5G TF and 5G NR Demodulation and Beamforming Analysis, Signal Analysis Bandwidth up to 100 MHz
Cable and antenna analysis up to 6 GHz, RF source and OTDR test for fronthaul, DAS and C-RAN. Interference hunting with InterferenceAdvisor software.
Specifications.

Spectrum Analyzer.
Frequency and time specifications:
  Option F001, 9 kHz to 6 GHz.
  Option F002, 9 kHz to 6 GHz and 24 GHz to 40 GHz.
  Option F018, 9 kHz to 18.5 GHz.
Frequency reference.
  Accuracy: ±0.05 ppm (0 to 50 °C (32 to 122 °F)) + aging.
  Accuracy with GPS: ±25 ppb GPS lock, ±50 ppb Hold over (72 hours).
  Aging: ±0.5 ppm/year, ±25 ppb with GPS.
Frequency span.
  Range: 0 Hz (zero span), 9 kHz to max frequency of each option.
  Resolution: 1 Hz.
  Accuracy: ±(2 x RBW centering + horizontal resolution).
Amplitude range.
Measurement range:
  9 kHz to 6 GHz: DANL to +25 dBm,
  > 6 GHz to 18.5 GHz: DANL to +25 dBm,
  24 GHz to 40 GHz: DANL to +15 dBm.

RF Power Meter Internal RF power sensor.
Frequency range:
  Option F001: 10 MHz to 6 GHz.
  Option F002: 10 MHz to 6 GHz and 24 GHZ to 40 GHz.
  Option F018: 10 MHz to 18.5 GHz.
Span: 1 kHz to max frequency of each option.
Dynamic range:
  10 MHz to 18.5 GHz: -100 to +25 dBm.
  24 GHz to 40 GHz: -100 to +15 dBm.
Maximum power:
  10 MHz to 18.5 GHz: +25 dBm.
  24 GHz to 40 GHz: +15 dBm.



 

Standard Calibration $980.00 *
*This is a Web introductory price for one calibration of the VIAVI CA5000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

POS
Packet over SONET/SDH (POS), is a communications protocol for transmitting packets in the form of the Point to Point Protocol (PPP) over SDH or SONET, which are both standard protocols for communicating digital information using lasers or light emitting diodes (LEDs) over optical fibre at high line rates.

TDMA: Time Division Multiple Access
Time Division Multiple Access (TDMA) is a method of sharing a communications carrier by assigning separate time slots to individual users. A channel is defined by a carrier frequency and time slot.


Please contact us for your VIAVI CA5000 CALIBRATION and/or VIAVI CA5000 CellAdvisor 5G REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*