EXTECH INSTRUMENTS EX540 CALIBRATION and EXTECH INSTRUMENTS EX540 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX540 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX540   Description / Specification:    
EXTECH INSTRUMENTS EX540 True RMS Wireless Digital Multimeter and Datalogger

The Extech EX540 is a True RMS wireless digital multimeter and datalogger offers wireless data streaming to a laptop or PC for datalogging or real-time monitoring. The EX540 transmits real-time data for monitoring, trending and analysis. In addition to wireless datalogging, the EX540 can log up to 9,999 readings internally and also reads voltage, current, resistance, capacitance, frequency (with dual-range sensitivity for electrical and electronic work), duty cycle, continuity, diode testing (2.8 volts), and even temperature (using its Type K thermistor bead probe). It features 0.06 percent accuracy that is a tough-to-beat, and a CAT IV-600-volt overvoltage safety rating, protecting users even on outdoor wiring. Several one-button data functions include minimum/maximum, relative, hold, and peak hold as well as selectable auto-ranging or manual-ranging.
Specifications.

Display Counts: 40,000 count.
Basic Accuracy: 0.06%.
DC/AC Voltage: 0.01mV to 1000VDC; 0.01mV to 1000VAC.
DC/AC Current: 0.01μA to 20A.
Resistance: 0.01Ωto 40MΩ.
Capacitance: 0.001nF to 40mF.
Frequency (electrical): 40Hz to 400Hz.
Frequency (electronic): 0.001Hz to 100MHz.
Temperature: -50 to 1382°F (-45 to 750°C).
Duty Cycle: 0.1 to 99.90%.
Diode/Continuity: Yes.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your EXTECH INSTRUMENTS EX540 CALIBRATION and/or EXTECH INSTRUMENTS EX540 True RMS Wireless Digital Multimeter and Datalogger REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: