GIGATRONICS 2520B CALIBRATION and GIGATRONICS 2520B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the GIGATRONICS 2520B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   GIGATRONICS 2520B   Description / Specification:    
GIGATRONICS 2520B 20 GHz Synthesized Microwave Sweeper

The Giga-Tronics 2520B Microwave Signal Generator delivers industry-best offset phase noise performance, high output power, and fast frequency switching speeds in a single unit. Performance features such as high time base stability, frequency modulation (FM), high-speed pulse/square wave modulation (PM), amplitude modulation (AM) and high leveled output power makes it an excellent test solution for a wide range of CW, modulation, swept frequency, and fast frequency switching applications in both R&D and manufacturing environment.
Specifications.

Frequency.
Range (with option 18): 100 kHz to 20 GHz.
Frequency Accuracy: Same as time base.
Frequency Resolution: 0.001 Hz.
Power Slope: 0 to 0.5 dB/GHz.
Phase Adjust: ± 360°.
Phase Adjust Resolution: 0.1°.

Frequency Stability.
Internal Reference Output 10 MHz: TTL level into 50 Ω.
Internal Reference Output 100 MHz: > +5 dBm square wave into 50 Ω.
Aging Rate: < 5 x 10-10/day.
Temperature Stability: < ± 2.5 x 10-8.

Output Power.
Maximum Leveled Output Power:
  10 dBm 0.1 to 10 MHz,
  12 dBm 0.01 to 2 GHz,
  14 dBm 2 to 20 GHz.
RF Power Level Accuracy option 26:
  ± 0.85 dB > +5 dBm,
  ± 0.7 dB +5 dBm to > -5 dBm,
  ± 1.2 dB -5 dBm to -90 dBm.
Minimum Leveled Output Power:
  -13 dBm 0.1 to 10 MHz,
  -10 dBm 0.01 to 20 GHz.

Options.
17A - Add Internal and External Modulation Suite (includes internal function generator).
17B - Add External Modulation Suite.
18 - Add 100 kHz to 2 GHz Frequency Range.
20 - Add High RF Output Power.
22 - Move RF Output Connector to Rear Panel.
23 - Add Type-N RF Connector.
26A - Add 90 dB Mechanical Step Attenuator.
28 - Add Ultra-Low Close-in Phase Noise.
29 - Add Fast Frequency Switching Speed.
32 - Add Narrow Pulse Width = 100 ns (Requires Option 17A or 17B).
44 - Replace Standard Front Panel with Blank Front Panel (Requires Option 22).
46 - Add Rack Slide Kit.



 

Standard Calibration $2,130.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the GIGATRONICS 2520B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your GIGATRONICS 2520B CALIBRATION and/or GIGATRONICS 2520B 20 GHz Synthesized Microwave Sweeper REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: