GIGATRONICS 2520B CALIBRATION and GIGATRONICS 2520B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the GIGATRONICS 2520B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   GIGATRONICS 2520B   Description / Specification:    
GIGATRONICS 2520B 20 GHz Synthesized Microwave Sweeper

The Giga-Tronics 2520B Microwave Signal Generator delivers industry-best offset phase noise performance, high output power, and fast frequency switching speeds in a single unit. Performance features such as high time base stability, frequency modulation (FM), high-speed pulse/square wave modulation (PM), amplitude modulation (AM) and high leveled output power makes it an excellent test solution for a wide range of CW, modulation, swept frequency, and fast frequency switching applications in both R&D and manufacturing environment.
Specifications.

Frequency.
Range (with option 18): 100 kHz to 20 GHz.
Frequency Accuracy: Same as time base.
Frequency Resolution: 0.001 Hz.
Power Slope: 0 to 0.5 dB/GHz.
Phase Adjust: ± 360°.
Phase Adjust Resolution: 0.1°.

Frequency Stability.
Internal Reference Output 10 MHz: TTL level into 50 Ω.
Internal Reference Output 100 MHz: > +5 dBm square wave into 50 Ω.
Aging Rate: < 5 x 10-10/day.
Temperature Stability: < ± 2.5 x 10-8.

Output Power.
Maximum Leveled Output Power:
  10 dBm 0.1 to 10 MHz,
  12 dBm 0.01 to 2 GHz,
  14 dBm 2 to 20 GHz.
RF Power Level Accuracy option 26:
  ± 0.85 dB > +5 dBm,
  ± 0.7 dB +5 dBm to > -5 dBm,
  ± 1.2 dB -5 dBm to -90 dBm.
Minimum Leveled Output Power:
  -13 dBm 0.1 to 10 MHz,
  -10 dBm 0.01 to 20 GHz.

Options.
17A - Add Internal and External Modulation Suite (includes internal function generator).
17B - Add External Modulation Suite.
18 - Add 100 kHz to 2 GHz Frequency Range.
20 - Add High RF Output Power.
22 - Move RF Output Connector to Rear Panel.
23 - Add Type-N RF Connector.
26A - Add 90 dB Mechanical Step Attenuator.
28 - Add Ultra-Low Close-in Phase Noise.
29 - Add Fast Frequency Switching Speed.
32 - Add Narrow Pulse Width = 100 ns (Requires Option 17A or 17B).
44 - Replace Standard Front Panel with Blank Front Panel (Requires Option 22).
46 - Add Rack Slide Kit.



 

Standard Calibration $2,130.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the GIGATRONICS 2520B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your GIGATRONICS 2520B CALIBRATION and/or GIGATRONICS 2520B 20 GHz Synthesized Microwave Sweeper REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: