KEYSIGHT N5221B CALIBRATION and KEYSIGHT N5221B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT N5221B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   KEYSIGHT N5221B   Description / Specification:    
KEYSIGHT N5221B 13.5 GHz PNA Microwave Network Analyzer

The Keysight N5221B is a 900 Hz / 10 MHz to 13.5 GHz PNA Microwave Network Analyzer, 2-ports with one source and 4-ports with two sources, source and receiver attenuators, bias-tees, pulse generators and modulators, noise figure, and best RF performance.
Specifications.

Maximum System Dynamic Range, Opt 200/400: 137 dB (3.2 GHz to 10 GHz, Port 1, 3), 135 dB (3.2 GHz to 10 GHz, Port 2, 4).
Maximum System Dynamic Range, Opt 201/401: 136 dB (3.2 GHz to 10 GHz, Port 1, 3), 135 dB (500 MHz to 2 GHz, Port 2, 4).
Maximum Receiver Dynamic Range: 131 dB (2 GHz to 13.5 GHz).
Test Ports: 3.5 mm (male), 50 ohm (nominal), (nominal), 0.002 in. (characteristic).

Test Port Output.
Frequency Range: 10 MHz to 13.5 GHz, 900 Hz to 13.5 GHz (LFE Options).
Frequency Resolution: 1 Hz.
Frequency Accuracy: ±0.7 ppm.
Initial Frequency Accuracy: ±0.2 ppm.
Frequency Stability Typical: ±0.05 ppm, -10° to 70° C.
Maximum Leveled Power, Opt 200/400/201/401: 13 dBm (50 MHz to 13.5 GHz, Port 1, 3), 13 dBm (50 MHz to 13.5 GHz, Port 2 , 4).

Test Port Input.
Maximum Test Port Noise Floor: -114 dBm (500 MHz to 13.5 GHz).

Hardware options.
N5221B-200 2-port, base hardware configuration.
N5221B-201 2-port with configurable test set, reference mixer switch.
N5221B-205 2-port with configurable test set, ref mixer switch, bias tees, low frequency extension.
N5221B-210 2-port with metrology configuration.
N5221B-217 2-port with configurable test set, reference mixer switch, source and receiver attenuators.
N5221B-219 2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees.
N5221B-220 2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension.
N5221B-400 4-port with second source.
N5221B-401 4-port with second source, configurable test set, reference mixer switch.
N5221B-405 4-port with second source, configurable test set, reference mixer switch, bias tees, low frequency extension.
N5221B-410 4-port with second source, metrology configuration.
N5221B-417 4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators.
N5221B-419 4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees.
N5221B-420 4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension.



 

Standard Calibration $780.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT N5221B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your KEYSIGHT N5221B CALIBRATION and/or KEYSIGHT N5221B 13.5 GHz PNA Microwave Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: