KEYSIGHT N5227B CALIBRATION and KEYSIGHT N5227B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT N5227B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   KEYSIGHT N5227B   Description / Specification:    
KEYSIGHT N5227B 67 GHz PNA Microwave Network Analyzer

The Keysight N5227B 10 MHz to 67 GHz PNA Microwave Network Analyzer has 2-ports with one source and 4-ports with two sources, source and receiver attenuators, bias-tees, pulse generators and modulators, noise figure, and best RF performance. It combines hardware and test software applications to measure a broad range of devices quickly and accurately. Parameterize your amplifier, mixer, and frequency converter behavior with advanced test software applications including noise figure, EVM, and pulsed-RF.
Specifications.

Maximum System Dynamic Range, Opt 200/400: 131 dB (10 GHz to 13.5 GHz, Port 1, 3), 132 dB (3.2 GHz to 10 GHz, Port 2, 4).
Maximum System Dynamic Range, Opt 201/401: 132 dB (10 GHz to 13.5 GHz, Port 1, 3), 132 dB (3.2 GHz to 10 GHz, Port 2, 4).
Maximum Receiver Dynamic Range: 133 dB (13.5 GHz to 26.5 GHz).
Test Ports: 1.85 mm (male), 50 ohm, (nominal), 0.002 in. (characteristic).

Test Port Output.
Frequency Range: 10 MHz to 67 GHz, 900 Hz to 67 GHz (LFE Options).
Frequency Resolution: 1 Hz.
Frequency Accuracy: ±0.7 ppm.
Initial Frequency Accuracy: ±0.2 ppm.
Frequency Stability Typical: ±0.05 ppm, -10° to 70° C.
Maximum Leveled Power: 13 dBm (3.2 GHz to 35 GHz, Opt 200/400), 13 dBm (3.2 GHz to 10 GHz, Opt 201/401).

Test Port Input.
Maximum Test Port Noise Floor: -117 dBm (24 GHz to 26.5 GHz).

Hardware options.
N5227B-200  2-port, base hardware configuration.
N5227B-201  2-port with configurable test set, reference mixer switch.
N5227B-205  2-port with configurable test set, ref mixer switch, bias tees, low frequency extension.
N5227B-210  2-port with metrology configuration
N5227B-219  2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees.
N5227B-220  2-port with configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension.
N5227B-400  4-port with second source.
N5227B-401  4-port with second source, configurable test set, reference mixer switch.
N5227B-405  4-port with second source, configurable test set, reference mixer switch, bias tees, low frequency extension.
N5227B-410  4-port with second source, metrology configuration.
N5227B-419  4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees.
N5227B-420  4-port with second source, configurable test set, reference mixer switch, source and receiver attenuators, bias tees, low frequency extension.



 



Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your KEYSIGHT N5227B CALIBRATION and/or KEYSIGHT N5227B 67 GHz PNA Microwave Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: