AMPROBE ACDC-620T CALIBRATION and AMPROBE ACDC-620T REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE ACDC-620T Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE ACDC-620T   Description / Specification:    
AMPROBE ACDC-620T 1000 Amp True RMS AC/DC Clamp Meter

The Amprobe ACDC-620T is a True RMS Clamp Meter for non-linear and traditional loads. It has a hold feature to capture glitch or in-rush current, a Data Hold to freeze displayed digital value, and differentiation reading for dual temperature measurement. It also has capacitor measurement and dynamic recording to help record the variation of the test. The hand guard prevents accidental contact with conductors.
Specifications / Features.

AC/DC Voltage: 0-399.9, 1000V ±(1% Rdg + 3 LSD) @ 0-1000VDC ±(1.5% Rdg + 3 LSD) @45-400Hz, 0-1000VAC.
AC/DC Current: 0-399.9, 1000A ±(1.5% Rdg + 3 LSD) @0-400A DC ±(2% Rdg + 5 LSD) @ 45-65Hz, 40-400A AC.
Resistance: 0-399.9Ω, 4.000kΩ, ±(1% Rdg + 3 LSD).
Capacitance: 0-399.9, 4000μF ±(3% Rdg + 4 LSD) @ 0-400μF.
Temperature: -40°F to 2500°F (-40°C to 1372°C) ±(0.5% Rdg + 6°F) (±0.5% Rdg + 3°C).
In-rush Peak Current Max (AC or DC): 0-399.9, 1000A ±(2% Rdg + 43 LSD).
Continuity Buzzer: <10.0Ω.
Diode Test: 1.65mA/< 3.3V.
UPC/DCI: 11929.
Safety: Designed to UL, ULc, CE, IEC & TUV Standards.
Relative(zero) function.
Auto and Manual Ranging.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your AMPROBE ACDC-620T CALIBRATION and/or AMPROBE ACDC-620T 1000 Amp True RMS AC/DC Clamp Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: