FLUKE I2000 CALIBRATION and FLUKE I2000 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE I2000 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE I2000   Description / Specification:    
FLUKE I2000 2000 Amp AC Current Probe

The Fluke i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. It has three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas, and is ideal for current measurement on thick and hard to reach conductors without breaking the circuit. The i2000 features a CAT III 600 V safety rating.
Specifications.

Maximum conductor diameter: 178 mm.
Current ranges: 20 A, 200 A, 2000 A, AC rms.
Output sensitivity (AC-coupled): 1 mV, 10 mV, 100 mV, 1 mV per A.
Load impedance: 100 kΩ minimum.
Accuracy (at +25°C): ±1% of range (45 Hz to 65 Hz).
Linearity (10% to 100% of range): ±0.2% of reading.
Noise: 8 mV AC rms (30 A) ; 2 mV AC rms (300 A, 3000 A).
Frequency range: 10 Hz to 20 kHz (-3 dB).
Phase error: < ±1° (45 Hz to 65 Hz) ; ±10° (at 20 kHz).
Position sensitivity (with cable > 25 mm from the coupling): From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range.
External wire influence: 1% (-40 db) of external current >200 mm from head.
External field: (with cable > 200 mm from the head) ±1% of range.
Temperature Coefficient: ±0.08% of reading per °C.
Working voltage: 600 V AC rms or DC.



 

Standard Calibration $260.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE I2000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your FLUKE I2000 CALIBRATION and/or FLUKE I2000 2000 Amp AC Current Probe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: