Keysight (Agilent) 8554L CALIBRATION and Keysight (Agilent) 8554L REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8554L Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Spectrum Analyzer Component?
Shop for Comparable Products on our
 used Spectrum Analyzer Component page

 
   Keysight (Agilent) 8554L   Description / Specification:    
Keysight (Agilent) 8554L Spectrum Analyzer RF Section

Spectrum Analyzer. RF Plug in covers a frequency range of 500kHz to 1250MHz. Amplitude accuracy to ±1.6 dB. Frequency accuracy to ±10 MHz. Input Impedance of 50 ? nominal. Maximum input level: peak or average power to input mixer <+ 13 dBm (1.4 V ac peak: ± 50 V dc). Calibrator: 30 MHz signal, -30 dBm ±0.3 dB. Vertical display calibration: (B divisions full-scale deflection), Logarthmic: calibrated directly in dBm over 130 dB range from -120 dBm to +10 dBm, 10 dB/div on 0 to 70 dB CRT display. Measurement accuracy at least ±2.0 dB using suitable measurement techniques, Linear: calibrated directly in V/div from 0.1 µV/div to 100 mV/div in a 1,2,10 sequence.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8554L. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your Keysight (Agilent) 8554L CALIBRATION and/or Keysight (Agilent) 8554L Spectrum Analyzer RF Section REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: