AMPROBE ACDC-3000 CALIBRATION and AMPROBE ACDC-3000 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE ACDC-3000 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE ACDC-3000 (ACDC3000)   Description / Specification:   Spec Sheet 
AMPROBE ACDC-3000 1000 Amp Digital AC/DC Clamp-on Multimeter

The Amprobe ACDC-3000 1000 Amp Digital AC/DC Clamp-on Multimeter features dynamic recording of Max, Min and Average readings, In-rush Peak Current capture (1 ms response), Dual Display of Amp & Freq., Amps & Duty Cycle, Voltage & Freq., Voltage & Duty Cycle and a 43 Segment, High speed, Analog Bar Graph. Specifications. AC Voltage: 0-3.999, 39.99, 399.9, 750V ±(1.5% Rdg + 5 LSD) @ 40-400 Hz. DC Voltage: 0-3.999, 39.99, 399.9, 1000V ±(0.5% Rdg + 3 LSD) @0-399.9 VDC. AC/DC Current: 0-39.99, 400.0, 1000A ±(1% Rdg + 2 LSD) ±(1% Rdg + 2 LSD). AC + DC TRMS Voltage: 0-3.999, 39.99, 399.9, 750V ±(2.5% Rdg + 9 LSD) @ 40-400 Hz. AC + DC TRMS Current: 0-39.99, 400.0, 1000A ±(3.5% Rdg + 9 LSD) @ 40-65 Hz, 40-400V. Resistance: 0-399.9 ohm, 3999 ohm, 4.00-39.99 Kohm, 40.0-399.9 Kohm, 0.400-3.999 Mohm, 39.99 Mohm ±(1% Rdg + 3 LSD) @ 400 ohm - 4 Mohm. Frequency: 10.00-199.99 Hz, 1999 Hz, 2.00-19.99 kHz, 199.9 kHz ±(0.2% Rdg + 4 LSD). % Duty Cycle: 0.0-99.9% ±(0.3% per kHz + 0.3%). Continuity Buzzer: <10.0 ohm built-in buzzer sounds when reading is below 100 mV. Diode Test: 1.65mA / <3.3V ±(1% Rdg + 2 LSD).



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE ACDC-3000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your AMPROBE ACDC-3000 CALIBRATION and/or AMPROBE ACDC-3000 1000 Amp Digital AC/DC Clamp-on Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: