ANDO AQ4320A REPAIR and ANDO AQ4320A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ANDO AQ4320A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANDO AQ4320A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Tunable Laser Source (TLS)?
Shop for Comparable Products on our
 used Tunable Laser Source (TLS) page or new Tunable Laser Source (TLS) page

 
   ANDO AQ4320A (AQ-4320A)   Description / Specification:    
ANDO AQ4320A 1480 to 1580 nm Tunable Laser Source

The Ando AQ4320A Tunable Laser Source Specifications. Wavelength range: 1480 to 1580nm. Wavelength set resolution: 0.001nm. Absolute wavelength accuracy: ±0.1nm. Relative wavelength accuracy: ±0.035nm (typ.). Wavelength stability: ±100MHz/hr (±0.8pm/hr) (typ.). Spectral width (Narrow): 1MHz or less, 200kHz (typ.). Spectral width (Wide): 200MHz or more. Side-Mode Suppression Ratio: 50dB or more/60dB (typ.). Optical output level (1550nm): +8dBm or more, +10dBm (typ.). Settable optical output range: 20dB or more (0.1dB steps). Optical output stability: 5 min, ±0.01dB or less; 1 hr, ±0.05dB or less; 8 hr, ±0.3dB or less. Optical output accuracy: ±1dB or less. Optical output reproducibility: ±0.04dB. Optical output level flatness: ±0.1dB. RIN: -145dB/Hz (typ.). Internal modulation (CHOP): Set frequency 0.2 to 300kHz; Set resolution 10Hz, 100Hz, 1kHz, 10kHz, 100kHz. External modulation (CHOP): Set frequency 0.2 to 300kHz. Direct modulation: Modulation frequency 100kHz to 300MHz; Modulation rate 5% or less; Modulation input level 0dBm or less. Wavelength sweep speed: 100nm/sec (Max.). Applicable optical fiber: SMF (10/125µm).



 

Standard Calibration $785.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANDO AQ4320A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your ANDO AQ4320A REPAIR and/or ANDO AQ4320A 1480 to 1580 nm Tunable Laser Source CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: