Custom-Cal has a high success rate in the repair of the ANDO AQ4321D. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANDO AQ4321D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Tunable Laser Source (TLS)?
Shop for Comparable Products on our
 used Tunable Laser Source (TLS) page or new Tunable Laser Source (TLS) page

 
   ANDO AQ4321D (AQ-4321D)   Description / Specification:    
ANDO AQ4321D 1520 to 1620 nm Tunable Laser Source

The Ando AQ4321D Tunable Laser Source Specifications. Wavelength range: 1520 to 1620 nm. Wavelength set resolution: 0.001nm. Wavelength stability: ±100 MHz/h (±0.8 pm/h) (typ.). Absolute wavelength accuracy: ±0.1nm, ±0.015 nm, ±0.01 nm (typ.). Relative wavelength accuracy: ±0.01 nm (typ.). Spectral width (Narrow): 200 kHz (typ.) (1 MHz or less). Spectral width (Wide): 200 MHz (typ.) (100 MHz or more). Side-Mode Suppression Ratio: 50 dB or more (optical output: +6 dBm, 1590 nm). Optical output +6 dBm or more, 1560 to 1600 nm; +7 dBm (typ.) peak. Settable optical output range: 20 dB or more (0.1 dB steps, at peak wavelength). Optical output stability: 5 min, ±0.01dB or less; 1 hr, ±0.05dB or less; 8 hr, ±0.3dB or less. Optical output accuracy: ±1dB or less. Optical output reproducibility: ±0.04 dB, optical output fixed. Optical output level flatness: ±0.1 dB ((1540 to 1600 nm)). RIN: -145dB/Hz (typ.). Internal modulation (CHOP): Set frequency 0.2 to 300kHz; Set resolution 10Hz, 100Hz, 1kHz, 10kHz, 100kHz. External modulation (CHOP): Set frequency 0.2 to 300kHz. Direct modulation: Modulation rate 5% or less (Modulation frequency: 100 kHz to 300 MHz, modulation input level: 0 dBm or less). Wavelength sweep speed: 100nm/sec (Max.). Applicable optical fiber: SMF (10/125µm).



 

Standard Calibration $785.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANDO AQ4321D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Time
Average time for the wave train to lose its phase realtionships

Fiber Bragg Grating (FBG)
A fiber Bragg grating (FBG) is a type of distributed Bragg reflector constructed in a short segment of optical fiber that reflects particular wavelengths of light and transmits all others. This is achieved by adding a periodic variation to the refractive index of the fiber core, which generates a wavelength specific dielectric mirror. A fiber Bragg grating can therefore be used as an inline optical filter to block certain wavelengths, or as a wavelength-specific reflector.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another. Adding information into pulses of light.

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, such as a fiber optic transmission system, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your ANDO AQ4321D REPAIR and/or ANDO AQ4321D 1520 to 1620 nm Tunable Laser Source CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: