ANDO AQ6315E REPAIR and ANDO AQ6315E CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ANDO AQ6315E. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANDO AQ6315E Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   ANDO AQ6315E (AQ-6315E)   Description / Specification:    
ANDO AQ6315E 350 to 1750 nm Optical Spectrum Analyzer

The Ando AQ6315E optical spectrum analyzer (OSA) is an improved version of the Ando AQ6315A. It covers 350 nm to 1750 nm range. The monochromator mode can be set to single-pass or double-pass to match your measurement application needs. The Ando AQ6315E includes analysis functions for DWDM and other optical devices (LD, LED, FBG, etc). Specifications. Measurement Wavelength Range: 350 to 1750 nm. Wavelength Accuracy: ± 0.5 nm (25 C, 10/125 SM Fiber), ± 0.05 nm (1510 to 1570 nm). Wavelength Linearity: ± 0.02 nm (1510 to 1570 nm). Wavelength Reproducibility: ± 0.005 nm (1 minute). Wavelength Resolution: 0.05 nm to 10 nm. Measurement Level Range: -90 to +20 dBm (1000 to 1650 nm single-pass monochromator mode), -85 to +20 dBm (1200 to 1600 nm double-pass monochromator mode). Level Accuracy: ±0.3 dB (1310 / 1550 nm). Level Linearity: ± 0.05 dB (0 to -20 dBm), ± 0.1 dB (0 to -40 dBm), ± 0.2 dB (0 to -60 dBm). Sensitivity: -65 dBm. Maximum Power: +20 dBm. Display: 9.4-inch color LCD. Built-in GPIB Interface. Three individual trace memories.



 

Standard Calibration $725.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANDO AQ6315E. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your ANDO AQ6315E REPAIR and/or ANDO AQ6315E 350 to 1750 nm Optical Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: