ANDO AQ6330 REPAIR and ANDO AQ6330 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ANDO AQ6330. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANDO AQ6330 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   ANDO AQ6330 (AQ-6330)   Description / Specification:    
ANDO AQ6330 1200 to 1750 nm Optical Spectrum Analyzer

The Ando AQ6330 is a portable optical spectrum analyzer developed as a measuring instrument compatible for the installation and maintenance of optical transmission systems such as the WDM system, by realizing compact and lightweight features. The measuring wavelength range is 1200 to 1700 nm and optical spectrum analysis is possible. In addition to such basic functions as high speed sweep, high sensitivity, high accuracy, broad dynamic range, and outstanding linearity, a wide variety of functions such as diverse data procssing functions and program measuring functions have all be included in this compact body weighing merely 8 kg, enabling the unit to be carried out around easily and used to perform advanced measurements at the site of installation and maintenance. Data output functions include making hard copies of the screen using the built in high speed printer or external printer, and reading/writing of the waveform program using the built in floppy disk. The unit comes equipped with the GP-IB and RS-232C interface as standard, the full remote control is possible.



Looking for a replacement? Try the  DEVISER AE8600

Standard Calibration $785.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANDO AQ6330. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a fiber optic component, link or network will operate.

Extinction Ratio (ER)
Extinction Ratio is the ratio of two optical power levels, of a digital signal generated by an optical source, (example a laser diode), where P1 is the optical power level generated when the light source is "on," and P0 is the power level generated when the light source is "off." The extinction ratio may be expressed as a fraction, in dB, or as a percentage.

Optical Signal-to-noise Ratio (OSNR)
Optical Signal-to-noise ratio is the ratio between the signal power and the noise power in a given bandwidth. Most commonly a reference bandwidth of 0.1 nm is used. This bandwidth is independent from the modulation format, the frequency and the receiver. For instance a OSNR of 20dB/0.1nm could be given, even the signal of 40 GBit DPSK would not fit in this bandwidth. OSNR is measured with a Optical Spectrum Analyzer. It is generally measured at the wavelength of interest.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.

Wavelength Repeatability
Wavelength Repeatability is the random uncertainty in reproducing a wavelength after detuning and re-setting the wavelength. The wavelength repeatability is ± half the span between the maximum and the minimum value of all actual values of these wavelengths. Example test condition: uninterrupted TLS output power, constant power level, temperature within operating temperature range, coherence control off, short time span. Note: NOTE The long-term wavelength repeatability can be obtained by taken the wavelength repeatability and wavelength stability into account.


Please contact us for your ANDO AQ6330 REPAIR and/or ANDO AQ6330 1200 to 1750 nm Optical Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: