ANRITSU 69147B CALIBRATION and ANRITSU 69147B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU 69147B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   ANRITSU 69147B   Description / Specification:   Spec Sheet 
ANRITSU 69147B 20 GHz Ultra Low Noise Synthesized Signal Generator

The Anritsu 69147B 20 GHz Ultra Low Noise Synthesized Signal Generator features 10 MHz to 20 GHz analog, step, and manual sweep capability. The 69147B also provides AM/FM/pulse modulation via external modulating signals. Output levels to +17 dBm and optional 0.1 Hz resolution are available at prices comparable to CW-only sources. To meet requirements that expand over time, economical upgrades are available to any higher performing model. Features, performance, and value combine to make the 69147B the optimum source for your network analysis and swept A.T.E. source applications. Specifications. Frequency range: 10 MHz to 20 GHz (Optional frequency extension down to 0.1 Hz). CW mode Output: Twenty independent, presettable CW frequencies (F0 to F9 and M0 to M9). CW mode Accuracy: Same as internal or external 10 MHz time base. CW mode Internal time base stability: With aging; <2 x 10–8/day (<5 x 10–10/day with Option 16), With temperature; <2 x 10–8/°C over 0°C (<2 x 10–10/°C with Option 16). CW mode Resolution: 1 kHz (0.1 Hz with Option 11). Analog Sweep width: Independently selected from 1 MHz to full range continuous sweep. Analog Sweep Accuracy: The lesser of ±30 MHz or (±2 MHz widths) for sweep speeds of <=50 MHz/ms. Output power: +13 dBm (+11 dBm with attenuator) >= 2 to < 20 GHz. Minimum leveled output power range: -20 dBm, (-120 dBm with attenuator). Output power resolution: 0.01 dB (log) or 0.001 mV (linear). Option 1 Rack mounting. Option 2A 110 dB step attenuator. Option 2F 120 dB electronic step attenuator. Option 9 Rear panel RF output. Option 11 0.1 Hz frequency resolution. Option 15A High power output. Option 16 High stability time base. Option 17A Delete front panel. Option 18 mmWave bias output. Option 19 SCPI programmability. Option 21 High spectral purity down converter. Option 22 0.1 Hz to 10 MHz audio frequency.



 

Standard Calibration $1,135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU 69147B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your ANRITSU 69147B CALIBRATION and/or ANRITSU 69147B 20 GHz Ultra Low Noise Synthesized Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: