ANRITSU MA9711A CALIBRATION and ANRITSU MA9711A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MA9711A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Power Sensor?
Shop for Comparable Products on our
 used Optical Power Sensor page or new Optical Power Sensor page

 
   ANRITSU MA9711A   Description / Specification:    
ANRITSU MA9711A 750 to 1800 nm GE Optical Power Sensor

The Anritsu MA9711A Optical Power Sensor is used with an ML9001A optical power meter. Specifications. Wavelength range: 0.75 to 1.8 µm. Element: Ge photodiode. Active area diameter: 5 mm. Optical power measurement range Continuous light (At 1.31 µm): -40 to +10 dBm (0.1 µW to 10 mW). Optical power measurement range Modulated light (At 1.31 µm, 270 Hz): -60 to +7 dBm (1 nW to 5 mW). Absolute Measurement accuracy (-23 dBm) for wavelengths other than 1.3 µm, specified at 23° ±5°C: ±5% (0.95 to 1.5 µm). Measurement accuracy linearity continuous light: 23°C, -23 dBm as reference: ±0.15 dB, (±0.45 dB for - 40 to -30 dBm). Resolution: W, W (REL) display: 0.1 to 1 %, dBm display: 0.01 dB, dB (REL) display: 0.001 dB.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MA9711A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your ANRITSU MA9711A CALIBRATION and/or ANRITSU MA9711A 750 to 1800 nm GE Optical Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: