ANRITSU ML2437A CALIBRATION and ANRITSU ML2437A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU ML2437A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Meter?
Shop for Comparable Products on our
 used RF Power Meter page

 
   ANRITSU ML2437A   Description / Specification:    
ANRITSU ML2437A Single Channel RF Power Meter

The Anritsu ML2437A Single Channel RF Power Meter combines the advantages of thermal meter accuracy, diode meter speed, and peak power meter display graphics. The result is a single instrument that achieves 90 dB dynamic range with a single sensor. It includes graphics display capability as a standard feature. The ruggedized housing and optional high-capacity NiMH battery bring convenience and accuracy to field service applications. Specifications. Frequency range: 10 MHz to 110 GHz (sensor dependent). Power sensors: Meter specifications apply to MA2400A series Power Sensors. Compatible with Anritsu MA and MP series sensors. Sensor Dynamic Range: MA2420A Series Fast Thermal Sensors: 50 dB, MA2440A Series High Accuracy Power Sensors: 87 dB CW, MA2470A Series Power Sensors: 90 dB CW. Power Measurement Range: –70 to +47 dBm (0.1 nW to 50W), sensor/attenuator dependent. Use couplers for higher power levels. Voltage Measurement Range: 0.00 to 20.00 V, nominal. Display Range: –99.999 to +99.999 dB. Display Resolution: Selectable from 0.1 dB to 0.001 dB limited to 0.01 dB in graphical display modes; Linear power units, 3 to 6 digit, 1 – 3 digits selectable to right of decimal nW – W; Voltage, 1 – 2 digits selectable to right of decimal. Display Units: dBm, dB, dBr, dBmV, dBmV, W, %, Volts. Instrument Accuracy: < 0.5 %. Trigger sources: Internal, External TTL, GPIB, Manual, Continuous.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU ML2437A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your ANRITSU ML2437A CALIBRATION and/or ANRITSU ML2437A Single Channel RF Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: