ANRITSU MP1764C REPAIR and ANRITSU MP1764C CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ANRITSU MP1764C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MP1764C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Error Detector?
Shop for Comparable Products on our
 used Error Detector page

 
   ANRITSU MP1764C   Description / Specification:    
ANRITSU MP1764C 12.5 GHz Error Detector

The Anritsu MP1764C 12.5 GHz Error Detector is used in combination with the MP1763C Pulse Pattern Generator are a BERTS (Bit Error Rate Test Set) supporting evaluation and testing of transmission equipment, high-speed devices, optical modules, etc., at every stage from R&D through to manufacturing and production at speeds from 50 Mbit/s to 12.5 Gbit/s. One MP1763C/MP1764C can cover the band from STM-0/STS-1 to 10 Gbit Ethernet, STM-64/STS-192, OTU-2 and can be used with 4.25 Gbit/s Fibre Channel Systems.
Specifications

Operation frequency: 0.05 to 12.5 GHz.

Data input
Input waveform: NRZ.
Input voltage: 0.25 to 2.0 Vp-p.
Threshold voltage variable range: -3.000 to + 1.875 Vp-p (1 mV steps).
Phase margin: >=70 ps (typical value at 10 Gb/s, PRSS 2^23 - 1, and an input amplitude of 1 Vp-p.
Input sensitivity: 50 mVp-p (typical value at 10 Gb/s and PRBS 2^23 - 1.

Clock input
Input waveform: Rectangular wave < 0.5 GHz), rectangular or sine wave (>=0.5 GHz), duty factor, 50%.
Input voltage: 0.25 to 2.0 Vp-p.
Input delay variable range: ±500 ps (1 ps steps).

Receive Pattern
Pseudorandom binary sequence pattern (PRBS):
Pattern: 2^n-1 (n: 7, 9, 11 , 15, 20, 23, 31),
Mark ratio: 1/2, 1/4, 1/8, 0/8 (1/2, 3/4, 7/8, 8/8 are possible with logic inversion).
Number of AND bit shift when setting mark ratio: 1, 3 bits (selectable by using DIP switch on rear panel).
Tracking: Information of pattern set by the error detector is sent to the pulse pattern generator via GPIB.

Options
01, Error Analysis.
02, Differential Data Input Function.
03, Clock Recovery Function.



 

Standard Calibration $1,815.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MP1764C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
Optical power referenced to 1 millimatt

Optical Time Domain Reflectometer (OTDR)
Optical Time Domain Reflectometer (OTDR) is a device for characterizing a fiber wherein an optical pulse is transmitted through the fiber and the resulting backscatter and reflections to the input are measured as a function of time. Useful in estimating attenuation coefficient as a function of distance and identifying defects and other localized losses.

Synchronous Transport Module (STM)
STM-1 (Synchronous Transport Module level-1) is the SDH ITU-T fiber optic network transmission standard. It has a bit rate of 155.52 Mbit/s. Other levels are STM-4, STM-16 and STM-64.


Please contact us for your ANRITSU MP1764C REPAIR and/or ANRITSU MP1764C 12.5 GHz Error Detector CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: