ANRITSU MS2717B CALIBRATION and ANRITSU MS2717B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS2717B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   ANRITSU MS2717B   Description / Specification:    
ANRITSU MS2717B 7.1 GHz Microwave Spectrum Analyzer

The Anritsu MS2717B 9 kHz to 7.1 GHz, Synthesized Spectrum Analyzereasily handles most RF and microwave spectrum analyzer needs. A wide 10 MHz demodulation bandwidth supports optional GSM, CDMA, W-CDMA, W-CDMA/HSDPA, EVDO, WiMAX and TD-SCDMA measurements. 512 MB Storage for 4,000 Traces and 4,000 Setups. Standard Built-in Preamplifier. Specifications. Frequency Range: 9 kHz to 7.1 GHz. Preamplifier: 100 kHz to 7.1 GHz. Frequency Span: 10 Hz to full frequency range, plus 0 Hz (zero span). Tuning Resolution: 1 Hz. Amplitude accuracy at 50 MHz: ± 0.7 dB (20° C to 30° C). Attenuator Range: 0 to 65 dB. Attenuator Resolution: 5 dB steps. Measurement Range: DANL to +30 dBm. Display Range: 1 to 15 dB/div in 1 dB steps Ten divisions displayed. Resolution Bandwidth: (–3 dB) 1 Hz to 3 MHz in 1-3 sequence ±10%, 200 Hz, 9 kHz, 120 kHz when quasi-peak detector selected. Sweep Time Zero span: 10 us to 600s. Display: 8.4 inch Color TFT Display (SVGA). Options. 001 - Rack Mount. 007 - Secure Data Operation. 009 - RF and Demodulation Hardware. 017 - GPIB Interface. 019 - High Accuracy Power Meter Functionality. 020 - Tracking Generator.



 

Standard Calibration $655.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MS2717B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your ANRITSU MS2717B CALIBRATION and/or ANRITSU MS2717B 7.1 GHz Microwave Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: