ANRITSU MS2719B CALIBRATION and ANRITSU MS2719B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS2719B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   ANRITSU MS2719B   Description / Specification:    
ANRITSU MS2719B 20 GHz Microwave Spectrum Analyzer

The Anritsu MS2719B 9 kHz to 20 GHz, Synthesized Spectrum Analyzereasily handles most RF and microwave spectrum analyzer needs. A wide 10 MHz demodulation bandwidth supports optional GSM, CDMA, W-CDMA, W-CDMA/HSDPA, EVDO, WiMAX and TD-SCDMA measurements. 512 MB Storage for 4,000 Traces and 4,000 Setups. Standard Built-in Preamplifier. Specifications. Frequency Range: 9 kHz to 20.0 GHz. Preamplifier: 100 kHz to 4.0 GHz. Frequency Span: 10 Hz to full frequency range, plus 0 Hz (zero span). Tuning Resolution: 1 Hz. Amplitude accuracy at 50 MHz: ± 0.7 dB (20° C to 30° C). Attenuator Range: 0 to 65 dB. Attenuator Resolution: 5 dB steps. Measurement Range: DANL to +30 dBm. Display Range: 1 to 15 dB/div in 1 dB steps Ten divisions displayed. Resolution Bandwidth: (–3 dB) 1 Hz to 3 MHz in 1-3 sequence ±10%, 200 Hz, 9 kHz, 120 kHz when quasi-peak detector selected. Sweep Time Zero span: 10 us to 600s. Display: 8.4 inch Color TFT Display (SVGA). Options. 001 - Rack Mount. 007 - Secure Data Operation. 009 - RF and Demodulation Hardware. 017 - GPIB Interface. 019 - High Accuracy Power Meter Functionality. 089 - IF Output.



 

Standard Calibration $655.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MS2719B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your ANRITSU MS2719B CALIBRATION and/or ANRITSU MS2719B 20 GHz Microwave Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: