ASSOCIATED RESEARCH 3765 REPAIR and CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ASSOCIATED RESEARCH 3765. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ASSOCIATED RESEARCH 3765   Description / Specification:   Spec Sheet 
ASSOCIATED RESEARCH 3765 5kV AC, 6kV DC Hipot with Ground Continuity Check

The Associated Research 3765 is a 5 kVAC 6 kVDC Hipot tester with an enhanced graphic LCD. It can be used as a bench-top instrument or controlled through entry-level automation with an RS-232 interface or with enhanced PLC Remote Control. It can also be interconnected to the HYAMP® III family of Ground Bond testers to form a complete test system that will perform AC Hipot and Ground Bond tests in a single DUT connection. It provides a simplified interface and the latest in technology & safety features. It is a perfect solution for entry level AC/DC Hipot testing applications. Specifications. Dielectric Withstand Test Mode Output Rating: 5000 V @ 20 mA AC, 6000 V @ 7.5 mA DC. Voltage Setting Range: 0 - 5.00 KV AC, 0 - 6.00 KV DC. Voltage Setting Resolution: 0.01 KV. Voltage Setting Accuracy: ± (2% of setting + 5 V) (Adjustable during operation. Disabled when key lockout is active). Maximum Limit AC Range: 0.00 - 20.00 mA, Resolution 0.01 mA. Maximum Limit DC Range: 0.00 - 7500 µA, Resolution 1 µA. Minimum Limit AC Range: 0.000 – 9.999 mA, Resolution: 0.001 mA. Minimum Limit DC Range: 0.000 – 999.9 µA, Resolution: 0.1 µA. Arc Detection Range: 0 – 9, 0 disabled. AC Voltage Waveform: Sine Wave, Crest Factor = 1.3 - 1.5. Output Frequency Range: 50 or 60 Hz, User Selectable. Ground Continuity Current: DC 0.1 A ± 0.01 A, fixed. Ground Continuity Range: 0.0 ohm - 1.50 ohm.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ASSOCIATED RESEARCH 3765. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: