ASSOCIATED RESEARCH 3670 CALIBRATION and ASSOCIATED RESEARCH 3670 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ASSOCIATED RESEARCH 3670 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ASSOCIATED RESEARCH 3670   Description / Specification:    
ASSOCIATED RESEARCH 3670 5kV AC, 6kV DC Hipot with IR and Ground Continuity Check

The Associated Research 3670 5KV AC, 6KV DC Hipot with Insulation Resistance and Ground Continuity Check has an enhanced Graphic LCD and entry-level automation with an RS-232 interface. Features. Remote Safety Interlock feature prevents the high-voltage from being activated without the interlock enabled. Electronic Ramp and Dwell timers for more consistent and reliable testing. Interconnects with an Associated Research Ground Bond tester to form a complete test system. Digitally controlled arc detection circuit allows the operator to program sensitivity levels for detecting arcs. Minimum and maximum trip settings for safer and more accurate testing. Specifications. Dielectric Withstand Test Mode Output Rating: 5000 V @ 20 mA AC, 6000 V @ 7.5 mA DC. Voltage Setting Range: 0 - 5.00 KV AC, 0 - 6.00 KV DC. Voltage Setting Resolution: 0.01 KV. Voltage Setting Accuracy: ± (2% of setting + 5 V). Maximum Limit AC Range: 0.00 - 20.00 mA, Resolution 0.01 mA. Maximum Limit DC Range: 0 - 7500 µA, Resolution 1 µA. Maximum Limit Accuracy: AC and DC ± (2% of setting + 2 counts). AC Voltage Waveform: Sine Wave, Crest Factor = 1.3 - 1.5, <2% THD. Output Frequency Range: 50 or 60 HZ, User Selectable. Ground Continuity Current: DC 0.1 A ± 0.01 A, fixed. Insulation Resistance Test Mode Voltage Setting Range: 30 - 1000 VDC, Accuracy ± (2% of setting + 5 V).



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ASSOCIATED RESEARCH 3670. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your ASSOCIATED RESEARCH 3670 CALIBRATION and/or ASSOCIATED RESEARCH 3670 5kV AC, 6kV DC Hipot with IR and Ground Continuity Check REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: