ASSOCIATED RESEARCH 3670 CALIBRATION and ASSOCIATED RESEARCH 3670 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ASSOCIATED RESEARCH 3670 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ASSOCIATED RESEARCH 3670   Description / Specification:    
ASSOCIATED RESEARCH 3670 5kV AC, 6kV DC Hipot with IR and Ground Continuity Check

The Associated Research 3670 5KV AC, 6KV DC Hipot with Insulation Resistance and Ground Continuity Check has an enhanced Graphic LCD and entry-level automation with an RS-232 interface. Features. Remote Safety Interlock feature prevents the high-voltage from being activated without the interlock enabled. Electronic Ramp and Dwell timers for more consistent and reliable testing. Interconnects with an Associated Research Ground Bond tester to form a complete test system. Digitally controlled arc detection circuit allows the operator to program sensitivity levels for detecting arcs. Minimum and maximum trip settings for safer and more accurate testing. Specifications. Dielectric Withstand Test Mode Output Rating: 5000 V @ 20 mA AC, 6000 V @ 7.5 mA DC. Voltage Setting Range: 0 - 5.00 KV AC, 0 - 6.00 KV DC. Voltage Setting Resolution: 0.01 KV. Voltage Setting Accuracy: ± (2% of setting + 5 V). Maximum Limit AC Range: 0.00 - 20.00 mA, Resolution 0.01 mA. Maximum Limit DC Range: 0 - 7500 µA, Resolution 1 µA. Maximum Limit Accuracy: AC and DC ± (2% of setting + 2 counts). AC Voltage Waveform: Sine Wave, Crest Factor = 1.3 - 1.5, <2% THD. Output Frequency Range: 50 or 60 HZ, User Selectable. Ground Continuity Current: DC 0.1 A ± 0.01 A, fixed. Insulation Resistance Test Mode Voltage Setting Range: 30 - 1000 VDC, Accuracy ± (2% of setting + 5 V).



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ASSOCIATED RESEARCH 3670. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your ASSOCIATED RESEARCH 3670 CALIBRATION and/or ASSOCIATED RESEARCH 3670 5kV AC, 6kV DC Hipot with IR and Ground Continuity Check REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: