ASSOCIATED RESEARCH 3505D CALIBRATION and ASSOCIATED RESEARCH 3505D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ASSOCIATED RESEARCH 3505D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ASSOCIATED RESEARCH 3505D   Description / Specification:    
ASSOCIATED RESEARCH 3505D 5KV AC Hypot II Dielectric Withstand Tester

The Associated Research 3505D Hypot II Dielectric Withstand tester has no load setup of trip current and output voltage. The Hypot II includes rear panel remote control connections to make it easier to build into an automated system. As an option, rear panel high voltage and return terminals can also be provided. Specifications. Output Rating AC: 0-5000V, 2V/step, 12 mA. Output Regulation: ± (1% of output + 5V). Voltage Setting: 0V-Max output rating, 10 volts/steps. Voltage Setting Accuracy: ± (2% of Setting + 5V). Output Frequency: 50/60 Hz selectable. Waveform: Sine wave, Distortion: < 2% THD. Dwell Time Setting: 0 and 0.2-999.9 second, 0.1 second/steps, "0" for continuous running. Ramp Time Setting: 0.2 - 999.9 seconds in 0.1 second increments, 0 ramp setting = 0.1 seconds fixed. Voltmeter (3 digits) Range: AC 0.00 - 5.00 KV, DC 0.00 - 6.00 KV. Ammeter (4 digits) Range: AC 0.10 - 12.00 mA, DC 0.02 - 5.00 mA. Ground Continuity Check: Current: DC 0.1A ± 0.01A, fixed, Max. ground resistance: 1 ohm ± 0.1 ohm, fixed. Low Current Sense: 0.00 - 12.00 mA AC. Low Current Sense Accuracy: ± (2% of setting + 0.02 mA). Options. 1-01, Rear Panel Outputs (HV, Return, Continuity). 2-03, Remote Interlock. 3-04, Arc Detection Function.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ASSOCIATED RESEARCH 3505D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your ASSOCIATED RESEARCH 3505D CALIBRATION and/or ASSOCIATED RESEARCH 3505D 5KV AC Hypot II Dielectric Withstand Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: