A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ASSOCIATED RESEARCH 3570D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ASSOCIATED RESEARCH 3570D   Description / Specification:    
ASSOCIATED RESEARCH 3570D 5KV AC, 6KV DC Hypot II Dielectric Withstand / IR Tester

The Associated Research 3565D Hypot II Dielectric Withstand tester has no load setup of trip current and output voltage. The Hypot II includes rear panel remote control connections to make it easier to build into an automated system. As an option, rear panel high voltage and return terminals can also be provided. Specifications. Output Rating AC: 0-5000V, 2V/step, 12 mA. Output Rating DC: 0-6000V, 2V/step, 5 mA. Output Regulation: ± (1% of output + 5V). Voltage Setting: 0V-Max output rating, 10 volts/steps. Voltage Setting Accuracy: ± (2% of Setting + 5V). Output Frequency: DC and 50/60 Hz selectable. Waveform: Sine wave, Distortion: < 2% THD. Ripple: < 5% at 6 KV DC/5 mA (DC mode only). Dwell Time Setting: 0 and 0.2-999.9 second, 0.1 second/steps, "0" for continuous running. Ramp Time Setting: 0.2 - 999.9 seconds in 0.1 second increments, 0 ramp setting = 0.1 seconds fixed. Voltmeter (3 digits) Range: AC 0.00 - 5.00 KV, DC 0.00 - 6.00 KV. Ammeter (4 digits) Range: AC 0.10 - 12.00 mA, DC 0.02 - 5.00 mA. Ground Continuity Check: Current: DC 0.1A ± 0.01A, fixed, Max. ground resistance: 1 ohm ± 0.1 ohm, fixed. Low Current Sense: 0.00 - 12.00 mA AC, 0.00 - 5.00 mA DC. Low Current Sense Accuracy: ± (2% of setting + 0.02 mA). IR Test Range: 1M-ohm to 1000 M-ohm. IR Test Accuracy: ± (3% of reading + 2 counts) > 500 Volts, ± (7% of reading + 2 counts) < 500 Volts. IR Test Voltage: 100 - 1000VDC in 10V step. IR Delay Range: 0, 0.5 - 999.9 seconds (0=constant). Options. 1-01, Rear Panel Outputs (HV, Return, Continuity). 2-03, Remote Interlock. 3-04, Arc Detection Function.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ASSOCIATED RESEARCH 3570D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your ASSOCIATED RESEARCH 3570D CALIBRATION and/or ASSOCIATED RESEARCH 3570D 5KV AC, 6KV DC Hypot II Dielectric Withstand / IR Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: