BK PRECISION 1655A CALIBRATION and BK PRECISION 1655A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 1655A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   BK PRECISION 1655A   Description / Specification:    
BK PRECISION 1655A 150V 3A Isolated-Variable AC Power Supply

The BK Precision 1655A Isolated-Variable AC Power Supply offers continuously variable output voltage from 0 to 150 VAC. It has a built in dual-purpose meter measures output voltage from 0 - 150 V and output current from 0 - 4A. Load calculations is not required if the measurement is made at the standard value of 120 volts. The 0 - 2 A and 0 - 4 A current scales are also calibrated as direct reading 0 - 24 VA and 0 - 480 VA scales. The 1655A 0 - 5mA (0 - 5000 µA) leakage scale is expanded in most commonly used 100 - 500 µA portion, compressed to 5 mA full scale. Overload protected. Specifications. Output Isolation: Leakage less than 0.1mA (25C, 50% relative humidity). Voltage Adjustment Range: 0 - 150 VAC, with input at 120 VAC. Voltage/Current Sensing: Sine wave average, calibrated in RMS. Maximum Current (Isolated): 3A continuous, 4A intermittent (0 - 130 V), Intermittent not to exceed 4 minutes at 4 A followed by 5 minutes at 1 A max.. Meter Scales Voltage: 0 - 150 V. Meter Scales Current: 0 - 2 A, 0 - 4 A. Meter Scales Volt-Amps (Voltage Set to 120): 0 - 240 VA, 0 - 480 VA. Meter Accuracy Volts: ±5% of full scale (calibrated @ 120VAC). Meter Accuracy Current: ±5% of full scale.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 1655A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your BK PRECISION 1655A CALIBRATION and/or BK PRECISION 1655A 150V 3A Isolated-Variable AC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: