BK PRECISION 1761 CALIBRATION and BK PRECISION 1761 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 1761 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   BK PRECISION 1761   Description / Specification:    
BK PRECISION 1761 Triple Output DC Power Supply

The B+K Precision 1761 Triple Output DC Power Supply is a high quality, general purpose dc power source. It provides two “main” supplies with a 0-35V volt dc output and a “third” output with a 2-6.5A volt dc output. The “main” V supplies are adjustable with both coarse and fine voltage controls for precise settability and are capable of current output of 0-3 amps. The “third” supply has a current output of 0-5 amps, allowing it to handle extensive digital logic circuitry. Two large panel-mounted LED meter displays can monitor either the output current or output voltage of each supply. The two “main” volt supplies can be operated independently or in one of two tracking modes. In the series tracking mode, the “B” Supply tracks from 5% to 100% of the voltage of the “A” Supply. Maximum current setting of the two supplies can still be set independently when in the series tracking operating mode. In the series tracking mode the “A” and “B” supplies are connected in series, allowing a single output of 0-70 V at up to 3 amps. In the parallel tracking mode, the two supplies are connected together in parallel, allowing a single 0-35 V output at up to 6 amps. Both “main” volt supplies may be used in constant voltage or constant current applications. The crossover from constant voltage to constant current modes is smooth and automatic. LED’s indicate the “CV” (constant voltage) or “CC” (constant current) mode of operation. Specifications “A” AND “B” supplies. Output Voltage Range: 0 V to 35 V. Output Current Limit Range: 0.1 A (5%) to 3 A. Load Regulation (Constant Voltage): =0.01% + 3 mV. Ripple (Constant Voltage): =1 mV RMS. Load Regulation (Constant Current): =0.2% + 3 mA. Line Regulation 108 - 132 V (Constant Current): =0.2% + 3 mA. Ripple Current (at 108 V for Constant Current): =3 mA RMS. Tracking (Series) Accuracy: ±0.2% + 10 mV. Panel Meter Accuracy (Volts): ±0.5% + 9 digits. Panel Meter Accuracy (Current): ±0.5% + 9 digits. Specifications “Third” supply. Output Voltage Range: 2 V to 6.5 V. Load Regulation (Constant Voltage)“Third”: =10 mV (0 to 5 A load). Line Regulation 108 - 132 V (Constant Voltage): =10 mV. Ripple and Noise: =2 mV RMS.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 1761. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your BK PRECISION 1761 CALIBRATION and/or BK PRECISION 1761 Triple Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: